Echocardiography
The full comprehensive echo, a step beyond the bedside FoCUS/POCUS scan: every standard window and view, chamber dimensions against ASE reference ranges, systolic and diastolic function, valve severity grading, the Doppler equations that make it quantitative, and the focused pathology that changes management at 3 a.m. Numbers are cited to the ASE, EACVI and BSE guidelines.
Related
On this page
Views & windowsChambers & dimensionsSystolic & diastolicValvesDoppler haemodynamicsFocused pathologyPro trackSourcesEducational reference only. Reference ranges and severity thresholds summarised here follow the ASE/EACVI chamber-quantification (2015), diastolic-function (2016) and valvular guidelines, and the BSE normal-values guideline, but cut-offs are vendor-, technique- and population-dependent and are refined over time (e.g. the 2023 ASE rheumatic heart disease recommendations, which treat a mitral valve area of 1.5 cm² or less as severe mitral stenosis, as ACC/AHA 2020 does). Grading is always an integrated judgement across multiple parameters, image quality and clinical context, never a single number. This page does not replace formal training, local protocols or a reporting physician. Always confirm against the current primary source.
- Severity grading is an integrated judgement across several parameters, image quality and clinical context, never a single number; cut-offs vary with vendor, technique and population.
- For 2D LVEF, use Simpson biplane (method of discs) from non-foreshortened A4C and A2C views; fractional shortening is only a linear surrogate and is invalid with regional wall-motion abnormalities.
- Assess RV systolic function by combining TAPSE, RV S′, fractional area change and free-wall strain, as no single number suffices; TAPSE is load- and angle-dependent.
- Grade aortic stenosis on peak velocity, mean gradient and continuity valve area, taking the highest CW velocity from several windows and measuring the LVOT diameter carefully, as it is squared.
- Tamponade is a clinical and echo diagnosis, not a matter of effusion size: a small, rapidly accumulating effusion can tamponade; look for RA systolic and RV diastolic collapse.
Explain it simply
- No single measurement decides how severe a heart problem is. The grade comes from several measurements, picture quality and the patient’s situation together, and cut-off values vary between machines, methods and groups of people.
- On 2D images, measure the main pumping chamber’s emptying by tracing it in two views from the heart’s tip, without cutting the tip short. A one-line shortcut fails if parts of the wall move abnormally.
- No one measurement shows how well the right side of the heart pumps, so combine several. One of them changes with the load on the heart and with the measuring angle.
- Judge how narrow the aortic valve is from three measurements together. Record the blood jet from several positions and use the fastest, and measure the outflow passage width carefully, because small errors are magnified.
- Whether fluid around the heart is squeezing it dangerously depends on the patient and the scan, not the amount. A small amount that builds quickly can do it; look for heart chambers being pressed in.
A guide only: follow your departmental protocols and regional requirements.
Standard views & acoustic windows
A complete TTE is built from four acoustic windows: parasternal, apical, subcostal and suprasternal. Patient in the left lateral decubitus for parasternal/apical (brings the heart to the chest wall), supine for subcostal/suprasternal. Marker convention below is for the ASE/cardiology orientation (index marker to patient’s left/cranial as noted).
Parasternal window
Parasternal long axis (PLAX)workhorse
ProbeLeft sternal edge, 3rd–4th intercostal space; index marker toward patient’s right shoulder (~10–11 o’clock).
ShowsRVOT (anterior), IVS, LV, posterior wall, aortic root & AV, LA, anterior/posterior mitral leaflets, descending thoracic aorta (posterior to LA).
MeasuresIVSd, LVIDd/LVIDs, LVPWd (M-mode/2D at leaflet tips); aortic sinus & sinotubular junction; LVOT diameter; LA A-P dimension; MV/AV M-mode (EPSS, box).
RV inflow & RVOTtilt off PLAX
ProbeFrom PLAX, tilt/angle toward the patient’s hip (inflow) or shoulder (outflow).
ShowsRA, tricuspid valve, RV inflow (inflow view): best CW alignment for the TR jet; pulmonary valve & main PA (RVOT view).
MeasuresTR Vmax (→ RVSP), pulmonary regurgitation, RVOT VTI.
Parasternal short axis (PSAX): the level seriesrotate 90°
From PLAX, rotate the probe ~90° clockwise (marker to left shoulder), then sweep from base to apex:
| Level | What you see | Key use |
|---|---|---|
| Aortic valve | “Mercedes” 3-cusp AV, surrounded by RA, TV, RVOT, PV, LA, IAS | AV morphology/bicuspid, TR jet (CW), PV, ASD/IAS, RVOT VTI |
| Mitral valve | “Fish-mouth” MV orifice | MV planimetry (MS area), leaflet motion |
| Papillary muscle | Circular LV, both papillary muscles | Regional wall motion (all 6 mid segments), D-shaped septum (RV pressure/volume overload), FS |
| Apex | Small circular LV cavity | Apical RWMA, thrombus, hypertrophy pattern |
Apical window
Apical 4-chamber (A4C)functional core
ProbePalpated apex (PMI), marker to patient’s left; angle beam toward the right scapula.
ShowsAll 4 chambers, mitral & tricuspid valves, IAS; RV free wall & TV annulus.
MeasuresSimpson biplane LVEF (with A2C), E/A & E/e’ (PW at MV tips + TDI at annulus), TAPSE & RV S’ (lateral TV annulus), TR Vmax, RV basal/mid diameters, LA volume (biplane).
Apical 5-chamber (A5C)anterior tilt
ProbeFrom A4C, tilt the beam anteriorly to bring the LVOT/AV into the plane (“5th chamber” = LVOT).
Shows / measuresLVOT & AV alignment for Doppler: LVOT VTI (PW), AV Vmax & mean gradient (CW) → continuity-equation AVA, stroke volume/cardiac output.
Apical 2-chamber (A2C) & 3-chamber (A3C / apical long axis)rotate
ProbeFrom A4C rotate counter-clockwise ~60° → A2C (LV + LA only, inferior & anterior walls); a further ~60° → A3C (adds LVOT/AV, like a PLAX from the apex).
MeasuresA2C: second plane for Simpson biplane EF & biplane LA volume; inferior/anterior RWMA. A3C: anterior-septal & inferolateral walls, LVOT Doppler alternative, MR jet.
Subcostal & suprasternal windows
Subcostal 4-chamber & IVCsupine
ProbeSub-xiphoid, patient supine/knees bent; marker to patient’s left. Rotate marker cranial for the IVC long-axis.
Shows / measures4 chambers (best for IAS/ASD and pericardial effusion; beam perpendicular to fluid), RV free-wall thickness; IVC diameter & collapsibility for RA pressure. Often the only window in a ventilated/arresting patient.
Suprasternal notchneck extended
ProbeIn the suprasternal notch, neck extended, marker toward the left ear.
Shows / measuresAortic arch & branches, descending aorta: coarctation, aortic dissection flap, and CW of the descending aorta for holodiastolic flow reversal (a sign of severe AR).
FreeChambers & dimensions: ASE reference ranges
Values from the ASE/EACVI 2015 chamber-quantification update (Lang et al.) unless noted. Dimensions are sex-specific; volumes and mass are indexed to body-surface area (BSA). Measure LV linear dimensions in PLAX (2D, at end-diastole/end-systole, at the leaflet-tip level, leading-edge to leading-edge for M-mode).
Left ventricle: walls & cavity (PLAX)
| Parameter | Men (normal) | Women (normal) | Notes |
|---|---|---|---|
| IVSd (septal thickness, diastole) | 0.6–1.0 cm | 0.6–0.9 cm | > upper limit → LVH concern; interpret with mass |
| LVPWd (posterior wall, diastole) | 0.6–1.0 cm | 0.6–0.9 cm | Symmetry vs asymmetric (HCM) matters |
| LVIDd (internal diameter, diastole) | 4.2–5.8 cm | 3.8–5.2 cm | Enlarged cavity ≈ dilated CM / volume load |
| LVIDs (internal diameter, systole) | 2.5–4.0 cm | 2.2–3.5 cm | Drives fractional shortening |
LV volumes, mass & geometry (indexed)
| Parameter | Men: normal (upper limit) | Women: normal (upper limit) |
|---|---|---|
| LV end-diastolic volume index (2D biplane) | ≤ 74 mL/m² | ≤ 61 mL/m² |
| LV end-systolic volume index | ≤ 31 mL/m² | ≤ 24 mL/m² |
| LV mass index (linear method; 2D method: ≤ 102 g/m² men, ≤ 88 g/m² women) | ≤ 115 g/m² | ≤ 95 g/m² |
| Relative wall thickness (RWT = 2·PWd/LVIDd) | ≤ 0.42 normal; > 0.42 = concentric geometry | |
Left atrium
| Parameter | Normal | Mild ↑ | Moderate ↑ | Severe ↑ |
|---|---|---|---|---|
| LA volume index (LAVI), biplane | 16–34 mL/m² | 35–41 | 42–48 | > 48 mL/m² |
| LA A-P diameter (PLAX), men / women | 3.0–4.0 / 2.7–3.8 cm | Diameter underestimates size; LAVI is preferred | ||
LAVI > 34 mL/m² is one of the four pillars of the diastolic-function algorithm and a marker of chronically raised filling pressure.
Right ventricle & aortic root
| Parameter | Normal | Abnormal cut-off |
|---|---|---|
| RV basal diameter (A4C, end-diastole) | < 4.1 cm | ≥ 4.1 cm = dilated |
| RV mid-cavity diameter | < 3.5 cm | ≥ 3.5 cm = dilated |
| RV free-wall thickness (subcostal) | < 0.5 cm | ≥ 0.5 cm = RVH (chronic pressure load) |
| TAPSE | > 1.7 cm | ≤ 1.7 cm = RV systolic dysfunction (ASE 2025) |
| RV S’ (TDI, lateral TV annulus) | > 9.5 cm/s | ≤ 9.5 cm/s = dysfunction (ASE 2025) |
| RV fractional area change (FAC) | > 35% | ≤ 35% = dysfunction |
| Aortic sinus of Valsalva (PLAX), indexed | ~ < 2.1 cm/m²; absolute > ~4.0 cm warrants attention (interpret with nomogram/BSA/age) | |
| LVOT diameter (for continuity/SV) | typically 1.8–2.2 cm; measured mid-systole, inner-edge to inner-edge in PLAX zoom | |
Systolic & diastolic function
LV systolic function: EF and its methods
Simpson biplane (method of discs): the recommended 2D method
Trace the LV endocardial border at end-diastole and end-systole in A4C and A2C. The software stacks discs to compute EDV and ESV.
EF = (EDV − ESV) / EDV × 100%
Non-foreshortened apical views are essential; a foreshortened apex is a recognised error: it underestimates volumes and can misstate EF.
Fractional shortening (FS) & eyeball
FS = (LVIDd − LVIDs) / LVIDd × 100%
Normal FS ≈ 25–45%. A linear surrogate only, invalid with regional wall-motion abnormalities (it samples only the basal septum/posterior wall). “Eyeball” visual EF by an experienced reader correlates well with Simpson but should be confirmed quantitatively when it changes management.
| LVEF category | Men | Women |
|---|---|---|
| Normal | 52–72% | 54–74% |
| Mildly reduced | 41–51% | 41–53% |
| Moderately reduced | 30–40% | 30–40% |
| Severely reduced | < 30% | < 30% |
Global longitudinal strain (GLS, speckle-tracking) detects subclinical dysfunction before EF falls; normal magnitude is more negative than about −20% (values closer to 0 are worse). Central to cardio-oncology surveillance.
RV systolic function
No single number suffices; combine TAPSE (≤ 1.7 cm abnormal), RV S’ TDI (≤ 9.5 cm/s abnormal), FAC (≤ 35% abnormal) and RV free-wall strain (cut-offs from the ASE 2025 right-heart guideline). TAPSE is load-dependent and angle-dependent (M-mode cursor must align with the lateral annulus in A4C).
Diastolic function: the ASE/EACVI 2016 algorithm
Superseded: the ASE 2025 diastolic-function update (Nagueh, Sanborn, Oh et al.) replaces this 2016 scheme with a new LA-pressure algorithm (age-specific e′, LA strain and separate pathways for groups such as atrial fibrillation); follow the version your laboratory uses. The 2016 scheme, summarised here, asks two questions: (1) with normal EF, is diastolic function normal or abnormal? and (2) with reduced EF, or myocardial disease with normal EF, are LV filling pressures raised, and what grade? Built on four variables:
| Variable | Abnormal cut-off | Meaning |
|---|---|---|
| Annular e′ (TDI) | septal e′ < 7 cm/s or lateral e′ < 10 cm/s | Impaired myocardial relaxation |
| Average E/e′ | > 14 | Raised LV filling pressure (surrogate for LAP/PCWP) |
| TR peak velocity | > 2.8 m/s | Elevated pulmonary pressure |
| LA volume index | > 34 mL/m² | Chronic pressure load on the LA |
| Grade | E/A | Filling pressure | Pattern |
|---|---|---|---|
| I: impaired relaxation | ≤ 0.8 with E ≤ 50 cm/s; or the grade II E/A band (≤ 0.8 with E > 50 cm/s, or > 0.8 and < 2) with 2 or more of the 3 criteria negative | Normal | Slow early filling; earliest change |
| II: pseudonormal | > 0.8 and < 2, or ≤ 0.8 with E > 50 cm/s | Elevated | Masked normal-looking E/A; ≥ 2 of E/e′>14, TRV>2.8, LAVI>34 positive |
| III: restrictive | ≥ 2 | Markedly elevated | Tall E, short deceleration time; worst prognosis |
Valves: grading severity
Severity grading is always integrated: no single parameter is definitive. Below are the ASE/EACVI headline cut-offs for the commonest lesions. Use the subsections.
Aortic (AS / AR)
Aortic stenosis (AS)
Measure the AV jet with CW from multiple windows (A5C, right parasternal, suprasternal); the highest velocity wins. Combine peak velocity, mean gradient and continuity-equation valve area.
| Parameter | Mild | Moderate | Severe |
|---|---|---|---|
| Peak jet velocity (Vmax) | 2.6–2.9 m/s | 3.0–3.9 m/s | ≥ 4.0 m/s |
| Mean gradient | < 20 mmHg | 20–39 mmHg | ≥ 40 mmHg |
| Aortic valve area (AVA) | > 1.5 cm² | 1.0–1.5 cm² | < 1.0 cm² |
| Indexed AVA | > 0.85 | 0.6–0.85 | < 0.6 cm²/m² |
| Dimensionless index (DVI) | — | < 0.25 = severe | |
AVA = (LVOT area × LVOT VTI) / AV VTI · DVI = LVOT VTI / AV VTI
Aortic regurgitation (AR)
| Parameter | Mild | Moderate | Severe |
|---|---|---|---|
| Jet width / LVOT (colour) | < 25% | 25–64% | ≥ 65% |
| Vena contracta width | < 0.3 cm | 0.3–0.6 cm | > 0.6 cm |
| Pressure half-time of AR jet (CW) | > 500 ms | 200–500 ms | < 200 ms |
| Descending aorta flow (PW) | brief early diastolic | intermediate | holodiastolic flow reversal |
| EROA / regurgitant volume | — | ≥ 0.30 cm² / ≥ 60 mL | |
Holodiastolic flow reversal in the proximal descending aorta (suprasternal view) is a robust sign of severe AR.
Mitral (MS / MR)
Mitral stenosis (MS)
Area by planimetry (PSAX MV level) is the anatomical gold standard; pressure half-time (PHT) is the classic Doppler method.
MVA (PHT) = 220 / pressure half-time (ms)
| Parameter | Mild | Moderate | Severe |
|---|---|---|---|
| Mitral valve area (MVA) | > 1.5 cm² | 1.0–1.5 cm² | < 1.0 cm²* |
| Mean transmitral gradient (HR-dependent) | < 5 mmHg | 5–10 mmHg | > 10 mmHg |
| PA systolic pressure | < 30 mmHg | 30–50 mmHg | > 50 mmHg |
Mitral regurgitation (MR)
Integrate colour jet, vena contracta and the quantitative PISA/EROA method; distinguish primary (degenerative) from secondary (functional); thresholds and prognosis differ.
| Parameter | Mild | Moderate | Severe |
|---|---|---|---|
| Vena contracta width | < 0.3 cm | 0.3–0.69 cm | ≥ 0.7 cm |
| EROA (PISA) | < 0.20 cm² | 0.20–0.39 cm² | ≥ 0.40 cm² |
| Regurgitant volume (primary) | < 30 mL | 30–59 mL | ≥ 60 mL |
| Regurgitant fraction | < 30% | 30–49% | ≥ 50% |
Tricuspid & pulmonary
Tricuspid regurgitation (TR)
Almost universal and usually trivial; grade the abnormal. The TR jet is also your window to RVSP (see the Doppler section).
| Parameter | Mild | Moderate | Severe |
|---|---|---|---|
| Vena contracta width | < 0.3 cm | 0.3–0.69 cm | ≥ 0.7 cm |
| EROA (PISA) | < 0.20 cm² | 0.20–0.39 cm² | ≥ 0.40 cm² |
| Hepatic vein flow | normal systolic-dominant | systolic blunting | systolic flow reversal |
| CW jet density / contour | soft, parabolic | dense | dense, triangular, early peak |
A dilated tricuspid annulus (> 40 mm / > 21 mm/m²) and hepatic-vein systolic reversal are hallmarks of severe (often functional) TR.
Pulmonary valve
- Pulmonary stenosis: severity by peak gradient: mild < 36 mmHg, moderate 36–64 mmHg, severe > 64 mmHg (peak velocity > 4 m/s).
- Pulmonary regurgitation: a trace jet is normal. Severe PR shows a wide colour jet at the annulus, dense CW signal with steep deceleration (short PR pressure half-time) and RV volume overload. Common late after tetralogy repair.
- PR end-diastolic velocity estimates PA diastolic pressure (4·V²end-diastolic PR + RA pressure); early-diastolic (peak) PR velocity estimates mean PA pressure (4·V²early PR + RA pressure).
Doppler haemodynamics: the equations
Doppler turns echo from anatomy into physiology. Five relationships do most of the clinical work.
1 · Simplified Bernoulli: velocity to pressure
ΔP = 4 × V² (mmHg, with V in m/s)
Converts any peak Doppler velocity across a restriction into a pressure gradient: the engine behind AS gradients, MS gradients, RVSP and gradients across a VSD. The full form subtracts the proximal velocity (4(V₂² − V₁²)); it’s simplified when V₁ is small, but not when the proximal velocity is high (e.g. serial obstructions, high LVOT velocity).
2 · RVSP from the TR jet + RA pressure (IVC)
RVSP = 4 × (TR Vmax)² + RA pressure
In the absence of RVOT obstruction/pulmonary stenosis, RVSP = pulmonary artery systolic pressure. Estimate RA pressure from the subcostal IVC:
| IVC diameter | Inspiratory collapse (sniff) | Estimated RA pressure |
|---|---|---|
| ≤ 2.1 cm | > 50% | 3 mmHg (0–5) |
| ≤ 2.1 cm | < 50% | 8 mmHg (intermediate) |
| > 2.1 cm | > 50% | 8 mmHg (intermediate) |
| > 2.1 cm | < 50% | 15 mmHg |
IVC collapse is unreliable in mechanically ventilated patients (positive-pressure reverses the physiology) and in athletes (baseline dilated IVC).
3 · Continuity equation: conservation of flow
A₁ × VTI₁ = A₂ × VTI₂
Flow entering equals flow leaving. Used for AVA (LVOT area × LVOT VTI = AVA × AV VTI) and for any effective orifice. The LVOT diameter is squared in the area term, so a 10% diameter error becomes a ~20% area error; measure it carefully in a zoomed PLAX.
4 · PISA (proximal isovelocity surface area)
As blood converges on a regurgitant orifice it forms hemispheric shells of equal velocity (aliasing at the shifted Nyquist limit). At the aliasing radius r:
Flow rate = 2π r² × Valiasing → EROA = Flow / Vregurgitant peak
Regurgitant volume = EROA × VTIregurgitant jet
Baseline shift the colour scale toward the jet to enlarge and clarify the PISA radius. Assumes a hemispheric, single, central orifice; eccentric or multiple jets and non-hemispheric geometry undermine it (a common pitfall in functional MR).
5 · Stroke volume & cardiac output (LVOT VTI)
SV = LVOT area × LVOT VTI = π (D/2)² × VTI · CO = SV × HR
The LVOT VTI (“stroke distance”) is a quick haemodynamic number: normal ~18–22 cm. A low LVOT VTI (< ~15 cm) flags low output and helps recognise low-flow AS, guides fluid responsiveness (VTI change with passive leg raise) and tracks output in shock.
FreeFocused & emergency pathology
Pericardial effusion & tamponade
Effusion size
- Small: < 10 mm echo-free space (diastole), often only posterior/systolic
- Moderate: 10–20 mm, circumferential
- Large: > 20 mm
Subcostal is best for perpendicular beam-to-fluid. Distinguish from a pleural effusion (tracks posterior to the descending aorta on PLAX) and an epicardial fat pad (anterior only, moves with the heart, echodense).
Tamponade: physiology > size
- RA systolic collapse (lasting > ⅓ of the cardiac cycle = nearly 100% sensitive and specific; ASE 2013)
- RV diastolic collapse (specific for raised intrapericardial pressure)
- Dilated, non-collapsing IVC (raised RA pressure)
- Respirophasic variation: mitral inflow E falls > 30%, tricuspid E rises > 60% with inspiration (echo pulsus paradoxus, ventricular interdependence)
- Septal “bounce” / swinging heart with electrical alternans
Acute RV strain / pulmonary embolism
| Sign | What it is | Why it matters |
|---|---|---|
| McConnell’s sign | Akinesia of the RV mid-free-wall with preserved apical contraction (“apical sparing”) | Relatively specific for acute RV pressure overload / PE |
| D-shaped septum | Systolic flattening of the IVS in PSAX (RV pressure overload) | Pressure overload flattens in systole; volume overload in diastole |
| 60/60 sign | Pulmonary acceleration time < 60 ms (mid-systolic notch) with TR peak gradient < 60 mmHg (TR Vmax ≤ 3.8 m/s) | Suggests acute overload; a chronically pressure-loaded RV generates higher gradients |
| RV dilation & dysfunction | RV ≥ LV, TAPSE ≤ 1.7 cm, dilated non-collapsing IVC | Marks right-heart strain and adverse prognosis in confirmed PE |
| Mobile thrombus-in-transit | Serpiginous mobile mass in RA/RV | High-risk; may prompt escalation of therapy |
Regional wall-motion abnormalities (RWMA)
Score each of the 17 (or 16) LV segments (normal/hyperkinetic, hypokinetic, akinetic, or dyskinetic), grouped by coronary territory:
LAD
Anterior wall, anterior septum, apex (± apical cap). Apical views + PSAX apex.
RCA
Inferior wall & basal-mid inferoseptum; often inferior RWMA with inferior STEMI. A2C + PSAX.
Circumflex
Inferolateral / anterolateral walls. A4C lateral + A3C.
A new RWMA in the right clinical setting is highly suggestive of ischaemia; a fixed thin, bright, akinetic segment suggests old infarct/scar. Watch for stress (“Takotsubo”) cardiomyopathy: apical ballooning that crosses coronary territories with a preserved base.
Cardiomyopathy patterns at a glance
| Pattern | Echo signature |
|---|---|
| Dilated CM | Dilated LV (↑LVIDd/EDVi), globally ↓EF, functional MR, ± LV thrombus |
| Hypertrophic CM | Asymmetric septal hypertrophy (septum:PW > 1.3–1.5), SAM of the MV, dynamic LVOT obstruction, small cavity |
| Restrictive / infiltrative | Normal-size non-dilated ventricles, biatrial enlargement, grade III diastolic dysfunction; amyloid: thick walls, “granular sparkling”, low GLS with apical sparing (“bullseye”) |
| Constrictive pericarditis (mimic) | Septal bounce, respirophasic septal shift, preserved/exaggerated medial e′ (annulus reversus), hepatic-vein expiratory diastolic reversal |
Pro track: the quantification & reporting workflow
Free previewEverything above is free. The Pro track will turn the reference numbers into a repeatable measurement and reporting routine: how expert sonographers acquire clean spectral traces, avoid the classic quantification traps, and write a structured report that a cardiologist trusts.
Quick self-check (free)
- AV Vmax 4.3 m/s, mean gradient 46 mmHg, AVA 0.8 cm²: grade? (Severe AS; all three concordant.)
- Septal e′ 6 cm/s, average E/e′ 16, TR Vmax 3.1 m/s, LAVI 40 mL/m², normal EF: diastolic function? (All 4 abnormal → diastolic dysfunction under the 2016 normal-EF step; filling pressure and grade then come from the second algorithm, which also needs E/A.)
- Dilated RV, TAPSE 1.4 cm, McConnell positive, TR Vmax 3.2 m/s, thin free wall: most likely? (Acute RV strain / PE, not chronic PH.)
Sources
Sources (25)
25 sources listed
- Lang RM, Badano LP, Mor-Avi V, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the ASE and EACVI. J Am Soc Echocardiogr 2015;28:1–39. (2015 chamber quantification.)
- Nagueh SF, Smiseth OA, Appleton CP, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography: an update from the ASE and EACVI. J Am Soc Echocardiogr 2016;29:277–314. Superseded by: Nagueh SF, Sanborn DY, Oh JK, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography and for heart failure with preserved ejection fraction diagnosis: an update from the American Society of Echocardiography. J Am Soc Echocardiogr 2025;38(7):537–569.
- Baumgartner H, Hung J, Bermejo J, et al. Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the EACVI and ASE. J Am Soc Echocardiogr 2017;30:372–392.
- Zoghbi WA, Adams D, Bonow RO, et al. Recommendations for noninvasive evaluation of native valvular regurgitation. J Am Soc Echocardiogr 2017;30:303–371.
- Baumgartner H, Hung J, Bermejo J, et al. Echocardiographic assessment of valve stenosis: EAE/ASE recommendations. J Am Soc Echocardiogr 2009;22:1–23.
- Rudski LG, Lai WW, Afilalo J, et al. Guidelines for the echocardiographic assessment of the right heart in adults (ASE). J Am Soc Echocardiogr 2010;23:685–713.
- Mitchell C, Rahko PS, Blauwet LA, et al. Guidelines for performing a comprehensive transthoracic echocardiographic examination in adults (ASE). J Am Soc Echocardiogr 2019;32:1–64.
- van de Bovenkamp AA, Enait V, de Man FS, et al. Validation of the 2016 ASE/EACVI guideline for diastolic dysfunction in patients with unexplained dyspnea and a preserved left ventricular ejection fraction. J Am Heart Assoc 2021;10(18):e021165. doi:10.1161/JAHA.121.021165
- Robinson S, Rana B, Oxborough D, et al. A practical guideline for performing a comprehensive transthoracic echocardiogram in adults: the BSE minimum dataset. Echo Res Pract 2020;7:G59–G93.
- Harkness A, Ring L, Augustine DX, et al. Normal reference intervals for cardiac dimensions and function for use in echocardiographic practice: a guideline from the British Society of Echocardiography. Echo Res Pract 2020;7:G1–G18.
- Wharton G, Steeds R, Allen J, et al. A minimum dataset for a standard adult transthoracic echocardiogram (BSE). Echo Res Pract 2015;2:G9–G24.
- Otto CM, Nishimura RA, Bonow RO, et al. 2020 ACC/AHA guideline for the management of patients with valvular heart disease. Circulation 2021;143:e72–e227.
- Vahanian A, Beyersdorf F, Praz F, et al. 2021 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J 2022;43:561–632.
- Konstantinides SV, Meyer G, Becattini C, et al. 2019 ESC guidelines for the diagnosis and management of acute pulmonary embolism. Eur Heart J 2020;41:543–603 (McConnell, 60/60, D-sign).
- Klein AL, Abbara S, Agler DA, et al. ASE recommendations for multimodality cardiovascular imaging of patients with pericardial disease. J Am Soc Echocardiogr 2013;26:965–1012.
- Adler Y, Charron P, Imazio M, et al. 2015 ESC guidelines for the diagnosis and management of pericardial diseases. Eur Heart J 2015;36:2921–2964.
- Voigt JU, Pedrizzetti G, Lysyansky P, et al. Definitions for a common standard for 2D speckle-tracking echocardiography (GLS). J Am Soc Echocardiogr 2015;28:183–193.
- Popescu BA, Andrade MJ, Badano LP, et al. EAE recommendations for training, competence and quality improvement in echocardiography. Eur J Echocardiogr 2009;10:893–905.
- Wu VC, Takeuchi M. Echocardiographic assessment of right ventricular systolic function. Cardiovasc Diagn Ther 2018;8:70–79.
- Right-heart echo reference values (normal TAPSE > 1.7 cm, S′ > 9.5 cm/s, FAC > 35%): ASE right-heart guideline 2025, Table 1, which updates ref 6: Mukherjee M, Rudski LG, Addetia K, et al. Guidelines for the echocardiographic assessment of the right heart in adults and special considerations in pulmonary hypertension. J Am Soc Echocardiogr 2025;38(3):141–186. ASE/EACVI 2015 (ref 1) gave TAPSE < 1.7 cm, S′ < 9.5 cm/s and FAC < 35% as abnormal.
- Pandian NG, Kim JK, Arias-Godinez JA, et al. Recommendations for the use of echocardiography in the evaluation of rheumatic heart disease: a report from the American Society of Echocardiography. J Am Soc Echocardiogr 2023;36(1):3–28. doi:10.1016/j.echo.2022.10.009 (correction doi:10.1016/j.echo.2023.01.016).
- Nishimura RA, Otto CM. Doppler haemodynamics: continuity equation, PISA and simplified Bernoulli (principles). In: The Practice of Clinical Echocardiography (Otto), 6th ed.
- Rudski LG. IVC and RA pressure estimation (3/8/15 mmHg scheme). See ref 6.
- Lang RM, et al. LV mass indexing and geometry (RWT thresholds). See ref 1.
- Galiè N, Humbert M, Vachiery JL, et al. 2015 ESC/ERS guidelines for pulmonary hypertension (echo probability, PA acceleration time). Eur Heart J 2016;37:67–119.
High Yield Imaging · Comprehensive TTE deep dive · Educational use only. Verify all thresholds against the current primary guideline before clinical application.
More in Clinical ultrasound
Next in Clinical ultrasound: MSK ultrasound
Educational reference for imaging professionals. It does not replace local policy, manufacturer labelling or clinical judgement.