Echocardiography

The full comprehensive echo, a step beyond the bedside FoCUS/POCUS scan: every standard window and view, chamber dimensions against ASE reference ranges, systolic and diastolic function, valve severity grading, the Doppler equations that make it quantitative, and the focused pathology that changes management at 3 a.m. Numbers are cited to the ASE, EACVI and BSE guidelines.

Related
On this pageViews & windowsChambers & dimensionsSystolic & diastolicValvesDoppler haemodynamicsFocused pathologyPro trackSources

Educational reference only. Reference ranges and severity thresholds summarised here follow the ASE/EACVI chamber-quantification (2015), diastolic-function (2016) and valvular guidelines, and the BSE normal-values guideline, but cut-offs are vendor-, technique- and population-dependent and are refined over time (e.g. the 2023 ASE rheumatic heart disease recommendations, which treat a mitral valve area of 1.5 cm² or less as severe mitral stenosis, as ACC/AHA 2020 does). Grading is always an integrated judgement across multiple parameters, image quality and clinical context, never a single number. This page does not replace formal training, local protocols or a reporting physician. Always confirm against the current primary source.

Key points
  • Severity grading is an integrated judgement across several parameters, image quality and clinical context, never a single number; cut-offs vary with vendor, technique and population.
  • For 2D LVEF, use Simpson biplane (method of discs) from non-foreshortened A4C and A2C views; fractional shortening is only a linear surrogate and is invalid with regional wall-motion abnormalities.
  • Assess RV systolic function by combining TAPSE, RV S′, fractional area change and free-wall strain, as no single number suffices; TAPSE is load- and angle-dependent.
  • Grade aortic stenosis on peak velocity, mean gradient and continuity valve area, taking the highest CW velocity from several windows and measuring the LVOT diameter carefully, as it is squared.
  • Tamponade is a clinical and echo diagnosis, not a matter of effusion size: a small, rapidly accumulating effusion can tamponade; look for RA systolic and RV diastolic collapse.
Explain it simply
  • No single measurement decides how severe a heart problem is. The grade comes from several measurements, picture quality and the patient’s situation together, and cut-off values vary between machines, methods and groups of people.
  • On 2D images, measure the main pumping chamber’s emptying by tracing it in two views from the heart’s tip, without cutting the tip short. A one-line shortcut fails if parts of the wall move abnormally.
  • No one measurement shows how well the right side of the heart pumps, so combine several. One of them changes with the load on the heart and with the measuring angle.
  • Judge how narrow the aortic valve is from three measurements together. Record the blood jet from several positions and use the fastest, and measure the outflow passage width carefully, because small errors are magnified.
  • Whether fluid around the heart is squeezing it dangerously depends on the patient and the scan, not the amount. A small amount that builds quickly can do it; look for heart chambers being pressed in.

A guide only: follow your departmental protocols and regional requirements.

Standard views & acoustic windows

A complete TTE is built from four acoustic windows: parasternal, apical, subcostal and suprasternal. Patient in the left lateral decubitus for parasternal/apical (brings the heart to the chest wall), supine for subcostal/suprasternal. Marker convention below is for the ASE/cardiology orientation (index marker to patient’s left/cranial as noted).

Parasternal window

Parasternal long axis (PLAX)workhorse

Probe

Left sternal edge, 3rd–4th intercostal space; index marker toward patient’s right shoulder (~10–11 o’clock).

Shows

RVOT (anterior), IVS, LV, posterior wall, aortic root & AV, LA, anterior/posterior mitral leaflets, descending thoracic aorta (posterior to LA).

Measures

IVSd, LVIDd/LVIDs, LVPWd (M-mode/2D at leaflet tips); aortic sinus & sinotubular junction; LVOT diameter; LA A-P dimension; MV/AV M-mode (EPSS, box).

Quality check: IVS horizontal, AV and MV both open in the plane, no foreshortening of the apex (apex should be off-screen; PLAX is not for the apex).

RV inflow & RVOTtilt off PLAX

Probe

From PLAX, tilt/angle toward the patient’s hip (inflow) or shoulder (outflow).

Shows

RA, tricuspid valve, RV inflow (inflow view): best CW alignment for the TR jet; pulmonary valve & main PA (RVOT view).

Measures

TR Vmax (→ RVSP), pulmonary regurgitation, RVOT VTI.

Parasternal short axis (PSAX): the level seriesrotate 90°

From PLAX, rotate the probe ~90° clockwise (marker to left shoulder), then sweep from base to apex:

LevelWhat you seeKey use
Aortic valve“Mercedes” 3-cusp AV, surrounded by RA, TV, RVOT, PV, LA, IASAV morphology/bicuspid, TR jet (CW), PV, ASD/IAS, RVOT VTI
Mitral valve“Fish-mouth” MV orificeMV planimetry (MS area), leaflet motion
Papillary muscleCircular LV, both papillary musclesRegional wall motion (all 6 mid segments), D-shaped septum (RV pressure/volume overload), FS
ApexSmall circular LV cavityApical RWMA, thrombus, hypertrophy pattern
Pearl: The papillary-muscle PSAX is the standard view for the interventricular septal shape (septal flattening and eccentricity index). A D-shape in systole = pressure overload, in diastole = volume overload.
Apical window

Apical 4-chamber (A4C)functional core

Probe

Palpated apex (PMI), marker to patient’s left; angle beam toward the right scapula.

Shows

All 4 chambers, mitral & tricuspid valves, IAS; RV free wall & TV annulus.

Measures

Simpson biplane LVEF (with A2C), E/A & E/e’ (PW at MV tips + TDI at annulus), TAPSE & RV S’ (lateral TV annulus), TR Vmax, RV basal/mid diameters, LA volume (biplane).

Quality check: the LV apex must be at the top of the sector and not foreshortened. Foreshortening underestimates volumes and can misstate EF. Use a dedicated RV-focused A4C for RV dimensions.

Apical 5-chamber (A5C)anterior tilt

Probe

From A4C, tilt the beam anteriorly to bring the LVOT/AV into the plane (“5th chamber” = LVOT).

Shows / measures

LVOT & AV alignment for Doppler: LVOT VTI (PW), AV Vmax & mean gradient (CW) → continuity-equation AVA, stroke volume/cardiac output.

Apical 2-chamber (A2C) & 3-chamber (A3C / apical long axis)rotate

Probe

From A4C rotate counter-clockwise ~60° → A2C (LV + LA only, inferior & anterior walls); a further ~60° → A3C (adds LVOT/AV, like a PLAX from the apex).

Measures

A2C: second plane for Simpson biplane EF & biplane LA volume; inferior/anterior RWMA. A3C: anterior-septal & inferolateral walls, LVOT Doppler alternative, MR jet.

Subcostal & suprasternal windows

Subcostal 4-chamber & IVCsupine

Probe

Sub-xiphoid, patient supine/knees bent; marker to patient’s left. Rotate marker cranial for the IVC long-axis.

Shows / measures

4 chambers (best for IAS/ASD and pericardial effusion; beam perpendicular to fluid), RV free-wall thickness; IVC diameter & collapsibility for RA pressure. Often the only window in a ventilated/arresting patient.

Suprasternal notchneck extended

Probe

In the suprasternal notch, neck extended, marker toward the left ear.

Shows / measures

Aortic arch & branches, descending aorta: coarctation, aortic dissection flap, and CW of the descending aorta for holodiastolic flow reversal (a sign of severe AR).

Free
A minimum “comprehensive” TTE (per ASE) runs the full sequence: PLAX + RV inflow/outflow, PSAX at all 4 levels, A4C/A5C/A2C/A3C with spectral & tissue Doppler, subcostal 4C + IVC, and suprasternal. Colour, PW/CW and TDI are layered onto the 2D views; the view is only “done” when both the anatomy and the required Doppler are captured.
Back to contents

Chambers & dimensions: ASE reference ranges

Values from the ASE/EACVI 2015 chamber-quantification update (Lang et al.) unless noted. Dimensions are sex-specific; volumes and mass are indexed to body-surface area (BSA). Measure LV linear dimensions in PLAX (2D, at end-diastole/end-systole, at the leaflet-tip level, leading-edge to leading-edge for M-mode).

Left ventricle: walls & cavity (PLAX)
ParameterMen (normal)Women (normal)Notes
IVSd (septal thickness, diastole)0.6–1.0 cm0.6–0.9 cm> upper limit → LVH concern; interpret with mass
LVPWd (posterior wall, diastole)0.6–1.0 cm0.6–0.9 cmSymmetry vs asymmetric (HCM) matters
LVIDd (internal diameter, diastole)4.2–5.8 cm3.8–5.2 cmEnlarged cavity ≈ dilated CM / volume load
LVIDs (internal diameter, systole)2.5–4.0 cm2.2–3.5 cmDrives fractional shortening
LV volumes, mass & geometry (indexed)
ParameterMen: normal (upper limit)Women: normal (upper limit)
LV end-diastolic volume index (2D biplane)≤ 74 mL/m²≤ 61 mL/m²
LV end-systolic volume index≤ 31 mL/m²≤ 24 mL/m²
LV mass index (linear method; 2D method: ≤ 102 g/m² men, ≤ 88 g/m² women)≤ 115 g/m²≤ 95 g/m²
Relative wall thickness (RWT = 2·PWd/LVIDd)≤ 0.42 normal; > 0.42 = concentric geometry
Geometry grid: normal mass + normal RWT = normal; normal mass + high RWT = concentric remodelling; high mass + high RWT = concentric hypertrophy; high mass + normal RWT = eccentric hypertrophy.
Left atrium
ParameterNormalMild ↑Moderate ↑Severe ↑
LA volume index (LAVI), biplane16–34 mL/m²35–4142–48> 48 mL/m²
LA A-P diameter (PLAX), men / women3.0–4.0 / 2.7–3.8 cmDiameter underestimates size; LAVI is preferred

LAVI > 34 mL/m² is one of the four pillars of the diastolic-function algorithm and a marker of chronically raised filling pressure.

Right ventricle & aortic root
ParameterNormalAbnormal cut-off
RV basal diameter (A4C, end-diastole)< 4.1 cm≥ 4.1 cm = dilated
RV mid-cavity diameter< 3.5 cm≥ 3.5 cm = dilated
RV free-wall thickness (subcostal)< 0.5 cm≥ 0.5 cm = RVH (chronic pressure load)
TAPSE> 1.7 cm≤ 1.7 cm = RV systolic dysfunction (ASE 2025)
RV S’ (TDI, lateral TV annulus)> 9.5 cm/s≤ 9.5 cm/s = dysfunction (ASE 2025)
RV fractional area change (FAC)> 35%≤ 35% = dysfunction
Aortic sinus of Valsalva (PLAX), indexed~ < 2.1 cm/m²; absolute > ~4.0 cm warrants attention (interpret with nomogram/BSA/age)
LVOT diameter (for continuity/SV)typically 1.8–2.2 cm; measured mid-systole, inner-edge to inner-edge in PLAX zoom
Golden rule for RV size: in a non-foreshortened A4C the RV should look smaller than the LV and should not share the apex. RV ≈ LV = moderately dilated; RV > LV and forming the apex = severely dilated.

Systolic & diastolic function

LV systolic function: EF and its methods

Simpson biplane (method of discs): the recommended 2D method

Trace the LV endocardial border at end-diastole and end-systole in A4C and A2C. The software stacks discs to compute EDV and ESV.

EF = (EDV − ESV) / EDV × 100%

Non-foreshortened apical views are essential; a foreshortened apex is a recognised error: it underestimates volumes and can misstate EF.

Fractional shortening (FS) & eyeball

FS = (LVIDd − LVIDs) / LVIDd × 100%

Normal FS ≈ 25–45%. A linear surrogate only, invalid with regional wall-motion abnormalities (it samples only the basal septum/posterior wall). “Eyeball” visual EF by an experienced reader correlates well with Simpson but should be confirmed quantitatively when it changes management.

LVEF categoryMenWomen
Normal52–72%54–74%
Mildly reduced41–51%41–53%
Moderately reduced30–40%30–40%
Severely reduced< 30%< 30%

Global longitudinal strain (GLS, speckle-tracking) detects subclinical dysfunction before EF falls; normal magnitude is more negative than about −20% (values closer to 0 are worse). Central to cardio-oncology surveillance.

RV systolic function

No single number suffices; combine TAPSE (≤ 1.7 cm abnormal), RV S’ TDI (≤ 9.5 cm/s abnormal), FAC (≤ 35% abnormal) and RV free-wall strain (cut-offs from the ASE 2025 right-heart guideline). TAPSE is load-dependent and angle-dependent (M-mode cursor must align with the lateral annulus in A4C).

Diastolic function: the ASE/EACVI 2016 algorithm

Superseded: the ASE 2025 diastolic-function update (Nagueh, Sanborn, Oh et al.) replaces this 2016 scheme with a new LA-pressure algorithm (age-specific e′, LA strain and separate pathways for groups such as atrial fibrillation); follow the version your laboratory uses. The 2016 scheme, summarised here, asks two questions: (1) with normal EF, is diastolic function normal or abnormal? and (2) with reduced EF, or myocardial disease with normal EF, are LV filling pressures raised, and what grade? Built on four variables:

VariableAbnormal cut-offMeaning
Annular e′ (TDI)septal e′ < 7 cm/s or lateral e′ < 10 cm/sImpaired myocardial relaxation
Average E/e′> 14Raised LV filling pressure (surrogate for LAP/PCWP)
TR peak velocity> 2.8 m/sElevated pulmonary pressure
LA volume index> 34 mL/m²Chronic pressure load on the LA
Screening step (normal EF): if < 50% of the 4 variables are abnormal → normal diastolic function; if > 50% abnormal → diastolic dysfunction (then estimate filling pressure and grade below); if exactly 50% → indeterminate. When systolic function is reduced or there is myocardial disease, go straight to grading.
GradeE/AFilling pressurePattern
I: impaired relaxation≤ 0.8 with E ≤ 50 cm/s; or the grade II E/A band (≤ 0.8 with E > 50 cm/s, or > 0.8 and < 2) with 2 or more of the 3 criteria negativeNormalSlow early filling; earliest change
II: pseudonormal> 0.8 and < 2, or ≤ 0.8 with E > 50 cm/sElevatedMasked normal-looking E/A; ≥ 2 of E/e′>14, TRV>2.8, LAVI>34 positive
III: restrictive≥ 2Markedly elevatedTall E, short deceleration time; worst prognosis
Caveats: the algorithm assumes sinus rhythm and no significant mitral valve disease, MAC, prosthesis or LVAD. AF, significant MR/MS, heavy annular calcification and constrictive/restrictive physiology all break the standard rules. Use alternative/ancillary parameters (pulmonary-vein flow, IVRT, L-wave, LA strain).
Back to contents

Valves: grading severity

Severity grading is always integrated: no single parameter is definitive. Below are the ASE/EACVI headline cut-offs for the commonest lesions. Use the subsections.

Aortic (AS / AR)

Aortic stenosis (AS)

Measure the AV jet with CW from multiple windows (A5C, right parasternal, suprasternal); the highest velocity wins. Combine peak velocity, mean gradient and continuity-equation valve area.

ParameterMildModerateSevere
Peak jet velocity (Vmax)2.6–2.9 m/s3.0–3.9 m/s≥ 4.0 m/s
Mean gradient< 20 mmHg20–39 mmHg≥ 40 mmHg
Aortic valve area (AVA)> 1.5 cm²1.0–1.5 cm²< 1.0 cm²
Indexed AVA> 0.850.6–0.85< 0.6 cm²/m²
Dimensionless index (DVI)—< 0.25 = severe

AVA = (LVOT area × LVOT VTI) / AV VTI  ·  DVI = LVOT VTI / AV VTI

Low-flow, low-gradient AS: when AVA < 1.0 cm² but mean gradient < 40 mmHg, check flow. If LVEF is low, a dobutamine stress echo distinguishes true-severe from pseudo-severe; if EF is normal, look for low stroke-volume index (< 35 mL/m²): “paradoxical” low-flow severe AS. Confirm LVOT diameter (it’s squared in the area; a major error source).

Aortic regurgitation (AR)

ParameterMildModerateSevere
Jet width / LVOT (colour)< 25%25–64%≥ 65%
Vena contracta width< 0.3 cm0.3–0.6 cm> 0.6 cm
Pressure half-time of AR jet (CW)> 500 ms200–500 ms< 200 ms
Descending aorta flow (PW)brief early diastolicintermediateholodiastolic flow reversal
EROA / regurgitant volume—≥ 0.30 cm² / ≥ 60 mL

Holodiastolic flow reversal in the proximal descending aorta (suprasternal view) is a robust sign of severe AR.

Mitral (MS / MR)

Mitral stenosis (MS)

Area by planimetry (PSAX MV level) is the anatomical gold standard; pressure half-time (PHT) is the classic Doppler method.

MVA (PHT) = 220 / pressure half-time (ms)

ParameterMildModerateSevere
Mitral valve area (MVA)> 1.5 cm²1.0–1.5 cm²< 1.0 cm²*
Mean transmitral gradient (HR-dependent)< 5 mmHg5–10 mmHg> 10 mmHg
PA systolic pressure< 30 mmHg30–50 mmHg> 50 mmHg
*Grading differs by guideline. This table follows EAE/ASE 2009 (moderate 1.0–1.5 cm², severe < 1.0 cm²); ACC/AHA 2020 treats MVA ≤ 1.5 cm² as severe MS, and ESC/EACTS 2021 treats MVA ≤ 1.5 cm² as clinically significant. Always report both the value and the guideline used. ASE’s 2023 rheumatic heart disease recommendations, which ASE now points to for mitral stenosis, also treat MVA ≤ 1.5 cm² as severe. PHT is invalidated by significant AR, tachycardia and immediately post-valvuloplasty. The Wilkins score (leaflet mobility, thickening, calcification, subvalvular) predicts suitability for balloon valvuloplasty.

Mitral regurgitation (MR)

Integrate colour jet, vena contracta and the quantitative PISA/EROA method; distinguish primary (degenerative) from secondary (functional); thresholds and prognosis differ.

ParameterMildModerateSevere
Vena contracta width< 0.3 cm0.3–0.69 cm≥ 0.7 cm
EROA (PISA)< 0.20 cm²0.20–0.39 cm²≥ 0.40 cm²
Regurgitant volume (primary)< 30 mL30–59 mL≥ 60 mL
Regurgitant fraction< 30%30–49%≥ 50%
Secondary (functional) MR: ASE 2017, ACC/AHA 2020 and ESC/EACTS 2021 use the same severe thresholds as for primary MR (EROA ≥ 0.40 cm², RVol ≥ 60 mL, RF ≥ 50%); ESC/EACTS 2021 notes that an EROA ≥ 0.30 cm² may already be severe with an elliptical orifice. The older EROA ≥ 0.20 cm² / RVol ≥ 30 mL boundary (ACC/AHA 2014, ESC 2017) is superseded. Supportive signs of severe MR: systolic pulmonary-vein flow reversal, dense triangular CW jet, and an enlarged LA/LV from chronic volume load.
Tricuspid & pulmonary

Tricuspid regurgitation (TR)

Almost universal and usually trivial; grade the abnormal. The TR jet is also your window to RVSP (see the Doppler section).

ParameterMildModerateSevere
Vena contracta width< 0.3 cm0.3–0.69 cm≥ 0.7 cm
EROA (PISA)< 0.20 cm²0.20–0.39 cm²≥ 0.40 cm²
Hepatic vein flownormal systolic-dominantsystolic bluntingsystolic flow reversal
CW jet density / contoursoft, parabolicdensedense, triangular, early peak

A dilated tricuspid annulus (> 40 mm / > 21 mm/m²) and hepatic-vein systolic reversal are hallmarks of severe (often functional) TR.

Pulmonary valve

  • Pulmonary stenosis: severity by peak gradient: mild < 36 mmHg, moderate 36–64 mmHg, severe > 64 mmHg (peak velocity > 4 m/s).
  • Pulmonary regurgitation: a trace jet is normal. Severe PR shows a wide colour jet at the annulus, dense CW signal with steep deceleration (short PR pressure half-time) and RV volume overload. Common late after tetralogy repair.
  • PR end-diastolic velocity estimates PA diastolic pressure (4·V²end-diastolic PR + RA pressure); early-diastolic (peak) PR velocity estimates mean PA pressure (4·V²early PR + RA pressure).

Doppler haemodynamics: the equations

Doppler turns echo from anatomy into physiology. Five relationships do most of the clinical work.

1 · Simplified Bernoulli: velocity to pressure

ΔP = 4 × V² (mmHg, with V in m/s)

Converts any peak Doppler velocity across a restriction into a pressure gradient: the engine behind AS gradients, MS gradients, RVSP and gradients across a VSD. The full form subtracts the proximal velocity (4(V₂² − V₁²)); it’s simplified when V₁ is small, but not when the proximal velocity is high (e.g. serial obstructions, high LVOT velocity).

2 · RVSP from the TR jet + RA pressure (IVC)

RVSP = 4 × (TR Vmax)² + RA pressure

In the absence of RVOT obstruction/pulmonary stenosis, RVSP = pulmonary artery systolic pressure. Estimate RA pressure from the subcostal IVC:

IVC diameterInspiratory collapse (sniff)Estimated RA pressure
≤ 2.1 cm> 50%3 mmHg (0–5)
≤ 2.1 cm< 50%8 mmHg (intermediate)
> 2.1 cm> 50%8 mmHg (intermediate)
> 2.1 cm< 50%15 mmHg

IVC collapse is unreliable in mechanically ventilated patients (positive-pressure reverses the physiology) and in athletes (baseline dilated IVC).

3 · Continuity equation: conservation of flow

A₁ × VTI₁ = A₂ × VTI₂

Flow entering equals flow leaving. Used for AVA (LVOT area × LVOT VTI = AVA × AV VTI) and for any effective orifice. The LVOT diameter is squared in the area term, so a 10% diameter error becomes a ~20% area error; measure it carefully in a zoomed PLAX.

4 · PISA (proximal isovelocity surface area)

As blood converges on a regurgitant orifice it forms hemispheric shells of equal velocity (aliasing at the shifted Nyquist limit). At the aliasing radius r:

Flow rate = 2π r² × Valiasing  →  EROA = Flow / Vregurgitant peak

Regurgitant volume = EROA × VTIregurgitant jet

Baseline shift the colour scale toward the jet to enlarge and clarify the PISA radius. Assumes a hemispheric, single, central orifice; eccentric or multiple jets and non-hemispheric geometry undermine it (a common pitfall in functional MR).

5 · Stroke volume & cardiac output (LVOT VTI)

SV = LVOT area × LVOT VTI = π (D/2)² × VTI  ·  CO = SV × HR

The LVOT VTI (“stroke distance”) is a quick haemodynamic number: normal ~18–22 cm. A low LVOT VTI (< ~15 cm) flags low output and helps recognise low-flow AS, guides fluid responsiveness (VTI change with passive leg raise) and tracks output in shock.

Free
Angle matters. Doppler measures the velocity component along the beam; every off-axis degree underestimates true velocity (cos θ). Interrogate each jet from multiple windows and report the highest; this is why AS is checked from A5C, right parasternal and suprasternal.
Back to contents

Focused & emergency pathology

Pericardial effusion & tamponade

Effusion size

  • Small: < 10 mm echo-free space (diastole), often only posterior/systolic
  • Moderate: 10–20 mm, circumferential
  • Large: > 20 mm

Subcostal is best for perpendicular beam-to-fluid. Distinguish from a pleural effusion (tracks posterior to the descending aorta on PLAX) and an epicardial fat pad (anterior only, moves with the heart, echodense).

Tamponade: physiology > size

  • RA systolic collapse (lasting > ⅓ of the cardiac cycle = nearly 100% sensitive and specific; ASE 2013)
  • RV diastolic collapse (specific for raised intrapericardial pressure)
  • Dilated, non-collapsing IVC (raised RA pressure)
  • Respirophasic variation: mitral inflow E falls > 30%, tricuspid E rises > 60% with inspiration (echo pulsus paradoxus, ventricular interdependence)
  • Septal “bounce” / swinging heart with electrical alternans
Tamponade is a clinical + echo diagnosis. A small effusion can tamponade if it accumulates rapidly (post-cardiac-surgery, trauma, iatrogenic); a large chronic effusion may not. Loculated effusions can compress a single chamber selectively.
Acute RV strain / pulmonary embolism
SignWhat it isWhy it matters
McConnell’s signAkinesia of the RV mid-free-wall with preserved apical contraction (“apical sparing”)Relatively specific for acute RV pressure overload / PE
D-shaped septumSystolic flattening of the IVS in PSAX (RV pressure overload)Pressure overload flattens in systole; volume overload in diastole
60/60 signPulmonary acceleration time < 60 ms (mid-systolic notch) with TR peak gradient < 60 mmHg (TR Vmax ≤ 3.8 m/s)Suggests acute overload; a chronically pressure-loaded RV generates higher gradients
RV dilation & dysfunctionRV ≥ LV, TAPSE ≤ 1.7 cm, dilated non-collapsing IVCMarks right-heart strain and adverse prognosis in confirmed PE
Mobile thrombus-in-transitSerpiginous mobile mass in RA/RVHigh-risk; may prompt escalation of therapy
Acute vs chronic clue: a thin (< 5 mm), dilated, poorly functioning RV that cannot generate a high RVSP (TR Vmax < ~3.8 m/s) points to an acute insult (PE). A thick RV free wall with a high RVSP indicates chronic pressure overload (e.g. pulmonary hypertension).
Regional wall-motion abnormalities (RWMA)

Score each of the 17 (or 16) LV segments (normal/hyperkinetic, hypokinetic, akinetic, or dyskinetic), grouped by coronary territory:

LAD

Anterior wall, anterior septum, apex (± apical cap). Apical views + PSAX apex.

RCA

Inferior wall & basal-mid inferoseptum; often inferior RWMA with inferior STEMI. A2C + PSAX.

Circumflex

Inferolateral / anterolateral walls. A4C lateral + A3C.

A new RWMA in the right clinical setting is highly suggestive of ischaemia; a fixed thin, bright, akinetic segment suggests old infarct/scar. Watch for stress (“Takotsubo”) cardiomyopathy: apical ballooning that crosses coronary territories with a preserved base.

Cardiomyopathy patterns at a glance
PatternEcho signature
Dilated CMDilated LV (↑LVIDd/EDVi), globally ↓EF, functional MR, ± LV thrombus
Hypertrophic CMAsymmetric septal hypertrophy (septum:PW > 1.3–1.5), SAM of the MV, dynamic LVOT obstruction, small cavity
Restrictive / infiltrativeNormal-size non-dilated ventricles, biatrial enlargement, grade III diastolic dysfunction; amyloid: thick walls, “granular sparkling”, low GLS with apical sparing (“bullseye”)
Constrictive pericarditis (mimic)Septal bounce, respirophasic septal shift, preserved/exaggerated medial e′ (annulus reversus), hepatic-vein expiratory diastolic reversal

Pro track: the quantification & reporting workflow

Free preview

Everything above is free. The Pro track will turn the reference numbers into a repeatable measurement and reporting routine: how expert sonographers acquire clean spectral traces, avoid the classic quantification traps, and write a structured report that a cardiologist trusts.

Free forever: all six teaching sections, every reference range, severity table and equation on this page stay open. Pro will add the guided doing: worksheets, flowcharts, cases and templates.

Quick self-check (free)

  1. AV Vmax 4.3 m/s, mean gradient 46 mmHg, AVA 0.8 cm²: grade? (Severe AS; all three concordant.)
  2. Septal e′ 6 cm/s, average E/e′ 16, TR Vmax 3.1 m/s, LAVI 40 mL/m², normal EF: diastolic function? (All 4 abnormal → diastolic dysfunction under the 2016 normal-EF step; filling pressure and grade then come from the second algorithm, which also needs E/A.)
  3. Dilated RV, TAPSE 1.4 cm, McConnell positive, TR Vmax 3.2 m/s, thin free wall: most likely? (Acute RV strain / PE, not chronic PH.)
Back to contents

Sources

Sources (25)

25 sources listed

  1. Lang RM, Badano LP, Mor-Avi V, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the ASE and EACVI. J Am Soc Echocardiogr 2015;28:1–39. (2015 chamber quantification.)
  2. Nagueh SF, Smiseth OA, Appleton CP, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography: an update from the ASE and EACVI. J Am Soc Echocardiogr 2016;29:277–314. Superseded by: Nagueh SF, Sanborn DY, Oh JK, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography and for heart failure with preserved ejection fraction diagnosis: an update from the American Society of Echocardiography. J Am Soc Echocardiogr 2025;38(7):537–569.
  3. Baumgartner H, Hung J, Bermejo J, et al. Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the EACVI and ASE. J Am Soc Echocardiogr 2017;30:372–392.
  4. Zoghbi WA, Adams D, Bonow RO, et al. Recommendations for noninvasive evaluation of native valvular regurgitation. J Am Soc Echocardiogr 2017;30:303–371.
  5. Baumgartner H, Hung J, Bermejo J, et al. Echocardiographic assessment of valve stenosis: EAE/ASE recommendations. J Am Soc Echocardiogr 2009;22:1–23.
  6. Rudski LG, Lai WW, Afilalo J, et al. Guidelines for the echocardiographic assessment of the right heart in adults (ASE). J Am Soc Echocardiogr 2010;23:685–713.
  7. Mitchell C, Rahko PS, Blauwet LA, et al. Guidelines for performing a comprehensive transthoracic echocardiographic examination in adults (ASE). J Am Soc Echocardiogr 2019;32:1–64.
  8. van de Bovenkamp AA, Enait V, de Man FS, et al. Validation of the 2016 ASE/EACVI guideline for diastolic dysfunction in patients with unexplained dyspnea and a preserved left ventricular ejection fraction. J Am Heart Assoc 2021;10(18):e021165. doi:10.1161/JAHA.121.021165
  9. Robinson S, Rana B, Oxborough D, et al. A practical guideline for performing a comprehensive transthoracic echocardiogram in adults: the BSE minimum dataset. Echo Res Pract 2020;7:G59–G93.
  10. Harkness A, Ring L, Augustine DX, et al. Normal reference intervals for cardiac dimensions and function for use in echocardiographic practice: a guideline from the British Society of Echocardiography. Echo Res Pract 2020;7:G1–G18.
  11. Wharton G, Steeds R, Allen J, et al. A minimum dataset for a standard adult transthoracic echocardiogram (BSE). Echo Res Pract 2015;2:G9–G24.
  12. Otto CM, Nishimura RA, Bonow RO, et al. 2020 ACC/AHA guideline for the management of patients with valvular heart disease. Circulation 2021;143:e72–e227.
  13. Vahanian A, Beyersdorf F, Praz F, et al. 2021 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J 2022;43:561–632.
  14. Konstantinides SV, Meyer G, Becattini C, et al. 2019 ESC guidelines for the diagnosis and management of acute pulmonary embolism. Eur Heart J 2020;41:543–603 (McConnell, 60/60, D-sign).
  15. Klein AL, Abbara S, Agler DA, et al. ASE recommendations for multimodality cardiovascular imaging of patients with pericardial disease. J Am Soc Echocardiogr 2013;26:965–1012.
  16. Adler Y, Charron P, Imazio M, et al. 2015 ESC guidelines for the diagnosis and management of pericardial diseases. Eur Heart J 2015;36:2921–2964.
  17. Voigt JU, Pedrizzetti G, Lysyansky P, et al. Definitions for a common standard for 2D speckle-tracking echocardiography (GLS). J Am Soc Echocardiogr 2015;28:183–193.
  18. Popescu BA, Andrade MJ, Badano LP, et al. EAE recommendations for training, competence and quality improvement in echocardiography. Eur J Echocardiogr 2009;10:893–905.
  19. Wu VC, Takeuchi M. Echocardiographic assessment of right ventricular systolic function. Cardiovasc Diagn Ther 2018;8:70–79.
  20. Right-heart echo reference values (normal TAPSE > 1.7 cm, S′ > 9.5 cm/s, FAC > 35%): ASE right-heart guideline 2025, Table 1, which updates ref 6: Mukherjee M, Rudski LG, Addetia K, et al. Guidelines for the echocardiographic assessment of the right heart in adults and special considerations in pulmonary hypertension. J Am Soc Echocardiogr 2025;38(3):141–186. ASE/EACVI 2015 (ref 1) gave TAPSE < 1.7 cm, S′ < 9.5 cm/s and FAC < 35% as abnormal.
  21. Pandian NG, Kim JK, Arias-Godinez JA, et al. Recommendations for the use of echocardiography in the evaluation of rheumatic heart disease: a report from the American Society of Echocardiography. J Am Soc Echocardiogr 2023;36(1):3–28. doi:10.1016/j.echo.2022.10.009 (correction doi:10.1016/j.echo.2023.01.016).
  22. Nishimura RA, Otto CM. Doppler haemodynamics: continuity equation, PISA and simplified Bernoulli (principles). In: The Practice of Clinical Echocardiography (Otto), 6th ed.
  23. Rudski LG. IVC and RA pressure estimation (3/8/15 mmHg scheme). See ref 6.
  24. Lang RM, et al. LV mass indexing and geometry (RWT thresholds). See ref 1.
  25. Galiè N, Humbert M, Vachiery JL, et al. 2015 ESC/ERS guidelines for pulmonary hypertension (echo probability, PA acceleration time). Eur Heart J 2016;37:67–119.

High Yield Imaging · Comprehensive TTE deep dive · Educational use only. Verify all thresholds against the current primary guideline before clinical application.

More in Clinical ultrasound

Next in Clinical ultrasound: MSK ultrasound

Educational reference for imaging professionals. It does not replace local policy, manufacturer labelling or clinical judgement.

Contents