MR angiography (MRA): Contrast and non-contrast techniques

MR angiography (MRA): Contrast and non-contrast techniques

Imaging blood vessels without ionising radiation, and increasingly without a contrast injection.

On this pageThe main techniquesCommon usesTrade-offsSources

The main techniques

  • Time-of-flight (TOF): non-contrast; bright flowing blood against saturated static tissue. Workhorse for the circle of Willis and carotids.
  • Phase-contrast (PC): encodes velocity and gives flow direction and quantification as well as anatomy.
  • Contrast-enhanced (CE-MRA): gadolinium-timed acquisition; fast, large-coverage, high-quality for aorta and peripheral runoff.
  • Newer non-contrast: e.g. quiescent-interval and balanced-SSFP methods for renal, peripheral and thoracic vessels.
Non-contrast MRA is especially valuable where gadolinium is best avoided (impaired renal function or repeated follow-up).

Common uses

  • Neurovascular: intracranial aneurysms, stenosis, dissection; carotid stenosis.
  • Aorta: aneurysm surveillance, dissection follow-up, coarctation.
  • Renal: renal artery stenosis.
  • Peripheral: runoff assessment in claudication/critical limb ischaemia.

Trade-offs

MRA avoids radiation and iodinated contrast but is slower and more motion-sensitive than CT angiography, and can overestimate stenosis (especially TOF). CTA is often preferred acutely for speed. Technique is matched to the vascular territory and the clinical question.

Scroll real scansBrain MRA atlas: real scans with the structures named on the image.

Sources

1 source listed

  1. Hartung MP et al. Magnetic resonance angiography: current status and future directions. J Cardiovasc Magn Reson 2011;13:19.

Educational summary for clinicians; technique choice follows local protocols. Not medical advice.

Vendor terminology
CE-MRA

General-purpose default; carotid, aorta, peripheral runoff.

✓SequencePlaneTRTETISlice/gapFOVMatrix/resOther
CE-MRA (3D spoiled GRE)CE-MRACE-MRACE-MRACE-MRACor 3Dminmin–1–1.5per station~1 mmFirst-pass Gd; test bolus / bolus tracking
Time-resolved CE-MRATWISTTRICKS4D-TRAKDRKStime-resolvedCor 3Dminmin–1.5–2per station~1.5 mmDynamic (TWIST/TRICKS/4D-TRAK)
TOF MRATOFTOFTOF (inflow)TOFoptional supplementAx 3D20–253–7–0.6–1200320Carotid / intracranial

CE-MRA vs TOF.60,61

What each sequence is for

Coronal 3D CE-MRA (spoiled GRE)
A fast 3D scan timed so contrast is bright in the arteries on its first pass. It shows narrowings, blockages and aneurysms, and a timing step (test bolus or bolus tracking) makes sure the arteries are caught before the veins fill.
Coronal time-resolved CE-MRA
Many fast 3D scans in a row show contrast flowing in and out, like a film. It shows the order in which vessels fill, which helps with abnormal artery-to-vein connections (fistulas and malformations) and reduces the need for exact timing.
Axial 3D TOF MRA, optional
No contrast needed: fresh flowing blood is bright. It adds detail of the carotid arteries or the arteries inside the head.

References: ACR–NASCI–SPR practice parameter: body MRA (2025); ACR–ASNR–SNIS–SPR practice parameter: MRA of the head and neck (2025).

Non-contrast MRA

When gadolinium is contraindicated. Ferumoxytol steady-state (off-label) for infants/small vessels.

✓SequencePlaneTRTETISlice/gapFOVMatrix/resOther
QISS (non-contrast MRA)QISSQISSQISSQISSAx/Cor ECG-gatedR-Rminquiescent2–3per station~1 mmPeripheral runoff; renal-safe
TOF MRATOFTOFTOF (inflow)TOFAx 3D20–253–7–0.6–1200320Carotid / intracranial
Balanced SSFPTrueFISPFIESTAbFFETrue SSFPnavigator, TSLIPCorminmininversion1.5–2300~1.3 mmRenal / aorta

QISS; non-contrast; ferumoxytol.60,61,62

What each sequence is for

Axial or coronal QISS, ECG-gated
A non-contrast method for the leg arteries: background tissue and veins are suppressed, and fresh arterial blood flows into the slice with each heartbeat, so the arteries are bright. Useful when contrast should be avoided, such as in severe kidney disease.
Axial 3D TOF MRA
Flowing blood is bright without contrast; it shows the carotid arteries and the arteries in the head.
Coronal balanced SSFP with inflow labelling, navigator
Bright-blood 3D imaging of the aorta and kidney arteries without contrast. A labelling pulse darkens the background and the veins so the arteries stand out, and the navigator times the scan to breathing.

References: ACR–NASCI–SPR practice parameter: body MRA (2025); QISS MRA review (Diagnostics 2018).

Vascular malformation (slow flow)

Suspected or known venous malformation of the soft tissues: extent and treatment planning. Ultrasound with Doppler usually comes first; contrast agent and dose per departmental protocol.

✓SequencePlaneTRTETISlice/gapFOVMatrix/resOther
STIRSTIRSTIRSTIRSTIRor T2 fat-sat / Dixon; large FOVCorlongas routine STIRfat nullper lesionlargeper lesionWhole lesion and neighbouring compartments
T2 TSE/FSET2 TSET2 FSET2 TSET2 FSEfat-sat (or Dixon)Axlonglong–4per lesionper lesionShape; relation to muscles, joint, tendons, nerves
T1 TSE/FSET1 TSET1 FSET1 TSET1 FSEno fat-satAxshortshort–3per lesionper lesionAnatomy, fat planes; clot or blood bright
T2* GREGRE (T2*)GRE (T2*)FFE (T2*)FE (T2*)optionalAxmoderatelong–per lesionper lesionper lesionPhleboliths and old blood bloom; fast flow bright
Time-resolved CE-MRATWISTTRICKS4D-TRAKDRKSstarts with the injectionCor 3Dminmin–2.5per lesionper lesionFrames of a few seconds; artery vs lesion filling
3D T1 spoiled GREVIBELAVATHRIVE3D Fast FE (Quick3D)fat-sat; pre, post and delayedAx 3Dminmin–3per lesionper lesionPre-contrast mask; repeat late; subtraction; drainage

ISSVA 2025; VASCERN 2023; ACR Appropriateness Criteria. TR and TE as shape words; slice values from one 1.5 T protocol.111,112,113,114,117

What each sequence is for

Coronal STIR, large field of view
Fat goes dark and the slow-flowing blood in the malformation stays bright, so this shows how far it spreads, often beyond what can be seen or felt. Cover the whole lesion and the neighbouring compartments, and run it before contrast.
Axial T2 fat-sat
Shows the channels as bright tubes or clusters and which muscles, joints, tendons and nerves they touch. With the axial T1 it is the reference pair before treatment.
Axial T1, no fat suppression
Gives the anatomy and the fat planes. Bright spots inside the channels can be fat, clot or old bleeding; clot is common in these malformations, and the pre-contrast T1 fat-sat tells fat from clot.
Axial T2* gradient echo, optional
Phleboliths (small calcified clots, a strong sign of a venous malformation) and old blood show as dark blooming dots, while fast-flowing vessels look bright.
Coronal time-resolved CE-MRA
Many fast 3D scans during the injection show when the lesion fills. A venous malformation fills late and gradually, after the neighbouring artery; a lesion that lights up with the arteries, with early draining veins, has fast flow, such as an AVM.
3D T1 fat-sat before and after contrast, with delayed series
Repeated over several minutes, it shows the venous channels slowly filling and where the lesion drains. A lymphatic malformation enhances only at its rim and septa. Subtracting the pre-contrast set, with identical settings and the patient still, leaves only the enhancement.

References: VASCERN-VASCA venous malformation pathways (2023); ACR Appropriateness Criteria: vascular malformations in children (2024); Imaging of peripheral vascular malformations (Mol Cell Pediatr 2021); MR imaging of vascular malformations (Pol J Radiol 2017); Dynamic flow sequences in vascular malformations (J Clin Med 2023); Intra-articular venous malformation of the knee (Pediatr Radiol 2020).

Pediatric
  • Free-breathing, navigator & DL-accelerated cine replace multiple breath-holds; validated in children (2025–2026).64
  • Ferumoxytol for CE-MRA / 4D flow in infants and small-caliber low-flow vessels, outperforming gadolinium under anesthesia.65
  • 4D flow suits complex CHD anatomy; use pediatric resolution (2–2.5 mm³).59

All protocols

Related

More in Cardiovascular

Where next: Liver iron and fat MRI

Educational reference for imaging professionals. It does not replace local policy, manufacturer labelling or clinical judgement.

Contents