MRI in dementia: Atrophy patterns and what it adds
Structural MRI does two jobs in cognitive decline: rule out something treatable, and read the pattern of brain shrinkage that points toward a diagnosis.
Overview
On this page
First job: exclude treatable causesSecond job: recognise atrophy patternsWhat it does and doesn’t doSourcesFirst job: exclude treatable causes
Before attributing decline to a neurodegenerative disease, MRI excludes potentially reversible or surgical causes: a tumour, subdural haematoma, normal-pressure hydrocephalus, or significant vascular disease. This alone justifies imaging in new cognitive impairment.

Second job: recognise atrophy patterns
Different dementias thin different regions, and the distribution is the clue:
| Pattern | Suggests |
|---|---|
| Medial temporal / hippocampal atrophy | Alzheimer’s disease |
| Frontal & anterior temporal atrophy | Frontotemporal dementia |
| Small-vessel disease, strategic infarcts | Vascular contribution |
| Relatively preserved medial temporal, occipital changes | Dementia with Lewy bodies (supportive) |
What it does and doesn’t do
MRI supports a clinical diagnosis and tracks change, but atrophy patterns overlap and are age-dependent; imaging is interpreted with the clinical picture and, increasingly, molecular biomarkers (PET, CSF). It is a pattern-recognition and exclusion tool, not a standalone diagnosis.
Sources
1 source listed
- Harper L et al. An algorithmic approach to structural imaging in dementia. J Neurol Neurosurg Psychiatry 2014;85:692–700.
Educational summary for clinicians; diagnosis is multidisciplinary. Not medical advice.
Protocol
Reformat coronal-oblique T1 through hippocampi for MTA (Scheltens); optional volumetry.
| ✓ | Sequence | Plane | TR | TE | TI | Slice/gap | FOV | Matrix/res | Other |
|---|---|---|---|---|---|---|---|---|---|
| 3D T1 IR-GREMPRAGEBRAVO / IR-FSPGR3D TFEFastFE 3Dcoronal-oblique reformat | Sag 3D | 2000 | 2–4 | ~900 | 1 iso | 240 | 256 | MTA ⟂ hippocampus | |
| FLAIRFLAIRFLAIRFLAIRFLAIR | Ax | 8000 | 120 | 2400 | 5 | 230 | 256 | Vascular burden | |
| T2 TSE/FSET2 TSET2 FSET2 TSET2 FSE | Ax | 4000 | 100 | – | 5 | 230 | 320 | – | |
| Susceptibility (SWI)SWISWANSWIpFSBB / SWI | Ax | 27 | 20–40 | – | 2–3 | 220 | 320 | Microbleeds / CAA | |
| DWI (SS-EPI)DWI (EPI)DWI (EPI)DWI (EPI)DWI (EPI/FASE) | Ax | 3000 | min | – | 4 | 230 | 160 | Exclude CJD/acute |
ESNR working group minimum protocol.18
What each sequence is for
- Sagittal 3D T1 IR-GRE, re-sliced coronal oblique
- A 3D volume re-sliced straight across the hippocampi. It shows how much the hippocampus has shrunk (the MTA score), which supports Alzheimer’s disease, and the pattern of shrinkage elsewhere points to other dementias.
- Axial FLAIR
- Shows small-vessel damage as bright patches in the white matter, and old strokes, which can cause or add to memory problems (vascular dementia).
- Axial T2
- A general check for other causes of memory problems, such as a tumour, old strokes or enlarged fluid spaces.
- Axial SWI
- Tiny old bleeds show as black dots. Many dots near the brain surface point to cerebral amyloid angiopathy, where amyloid builds up in the walls of small vessels.
- Axial DWI
- Shows a recent small stroke, and the bright cortex or deep grey matter of Creutzfeldt–Jakob disease (CJD), a rare cause of rapidly worsening dementia.
References: ESNR working group dementia protocol (Neuroradiology 2019); Boston criteria v2.0 for cerebral amyloid angiopathy (Lancet Neurol 2022); ACR–ASNR–SPR practice parameter: MRI of the brain (2024).
Positioning

- Head coil around the head
- Wedge under the knees
- Call bell in the hand
- Position
- Supine, head first, with a support under the knees.
- Coil
- head coildS Head coilHead/Neck 20 or 64 coil. Usually the body coil transmits and the head coil only receives; some head coils transmit as well.
- Centre
- The centre mark of the head coil.
- Set up
- Slide the patient up until the shoulders touch the coil, so the headphones sit over the ears and the coil top closes cleanly.
- Earplugs in, headphones on, call bell in hand.
- Small head: pack foam pads either side so the head cannot roll.
- Straighten the head before the coil top goes on: nose up, not tilted or turned.
- What goes wrong, and the fix
- Head too big for the coil top with headphones on: change to slimmer passive ear defenders and take out the pad under the head; then check they can still hear you.
- Head rolls or nods during the scan: add pads around the head and check comfort; a radial motion-correctingMultiVane XDBLADE T2 can reduce motion artefact.
- Patient anxious in the closed coil: explain the scan, talk between sequences, and keep the call bell in reach.
- Check on the first localisersurveylocalizer
- The whole brain sits inside the coil’s signal on the sagittal and coronal localisersurveylocalizer.
- The head is not rotated or tilted; if it is badly off, straighten it now rather than angling every sequence.
Explain it simply
The head goes inside a cage-like coil that picks up the signal. Pads stop it rolling, and earplugs and headphones protect the ears from the noise.
Why it matters: A straight, still head gives symmetrical images that are easier to compare side to side.
Sources: Department notes; Zaitsev 2015; ACR MR Safety 2026; MHRA 2026; Gruber 2018
Reading it
Systematic search order
- Symmetry first: compare left vs right hemispheres, then descend cranial → caudal.
- Grey–white differentiation & cortex: ribbon, sulci, gyral pattern.
- Deep structures: basal ganglia, thalami, internal capsules.
- Ventricles & CSF spaces: size, symmetry, ependymal margins.
- Midline & posterior fossa: corpus callosum, brainstem, cerebellum, 4th ventricle.
- Then the review areas (below), the peripheral belt that the parenchymal search skips.
Key structures × sequence
| Structure | Best on | Looking for |
|---|---|---|
| Acute infarct | DWI + ADC | Restricted diffusion (bright DWI, dark ADC). Must-check on every brain. |
| Oedema / gliosis / demyelination | FLAIR | Periventricular & juxtacortical hyperintensity; sulcal FLAIR signal (SAH, meningitis). |
| Microbleeds / haemorrhage / calcium | SWI / GRE | Blooming foci: amyloid, cavernoma, DAI, haemorrhagic mets. |
| Enhancing lesion / breakdown | T1 post-Gd | Tumour, abscess rim, leptomeningeal & dural enhancement. |
| Anatomy / marrow / fat planes | T1 | Skull base marrow, clival signal, orbital fat. |
Review areas
- Skull base & clivus: marrow replacement, chordoma, sphenoid lesions (T1).
- Cavernous sinuses: asymmetry, convexity, ICA flow voids, CN III–VI (coronal post-Gd).
- Internal auditory canals (IACs) & CPA: vestibular schwannoma, enhancement (thin post-Gd / heavily T2).
- Pituitary & sella: microadenoma, stalk position, height/convexity of gland.
- Extra-axial spaces: thin subdural/epidural collections that parallel the calvarium.
- Vessels & flow voids: absent flow void (thrombosis/occlusion), aneurysmal flow void, dural venous sinuses.
- Orbits & globes: optic nerves/sheaths, extra-ocular muscles, orbital apex.
- Paranasal sinuses & mastoid air cells: fluid, mucosal disease, opacification.
- Calvarium & scalp: lytic/blastic lesions, marrow signal, subgaleal collections.
- Cervicomedullary junction & foramen magnum: tonsillar position (Chiari), cord signal at the bottom slice.
Tick-off checklist
Printable review list. Checkboxes reset on reload (no data stored).
More in Neuro
Next in Neuro: Pituitary MRI
Educational reference for imaging professionals. It does not replace local policy, manufacturer labelling or clinical judgement.