Rheumatoid hand and wrist MRI: Early synovitis and erosions
In inflammatory arthritis, damage prevention depends on catching disease early; MRI sees the inflammation and the first erosions long before plain films do.
Overview
What MRI adds over X-ray
Plain radiographs show established erosions, i.e. damage that has already happened. MRI (often with contrast) reveals the active inflammation and the earliest bone changes, supporting earlier diagnosis and a treat-to-target approach.
The three key findings
- Synovitis: enhancing thickened synovium, the active inflammatory driver.
- Bone-marrow oedema (osteitis): predicts erosive progression.
- Erosions: detected earlier and in more joints than on X-ray.
Tenosynovitis is also well shown and contributes to symptoms and damage. The RAMRIS system scores these for research and monitoring.
Use in practice
MRI (and ultrasound) helps in early/undifferentiated arthritis, in assessing subclinical inflammation, and in monitoring response. Findings are integrated with clinical assessment and serology (RF, anti-CCP) rather than used alone.
Sources
1 source listed
- Østergaard M et al. OMERACT rheumatoid arthritis MRI scoring system (RAMRIS) and updates.
Educational summary for clinicians; diagnosis is clinical-serological-imaging. Not medical advice.
Positioning

- Fingers and thumb taped together
- Thumb alongside the hand, not tucked under
- Hand flat on a long sponge
- Coil open; it closes before scanning
- Position
- Prone in the superman position, affected hand overhead.
- Coil
- small wrap-around extremity coildS Small Extremity coilUltraFlex Small 18 coil.
- Centre
- The middle of the hand and wrist.
- Set up
- Towel under the armpit; shoulder flat.
- Tape the fingers and thumb together gently so there are no air gaps, without bending or squeezing any joint.
- Hand and fingers straight, in line with the forearm, flat on a long straight sponge.
- Thumb alongside the hand, not tucked under the palm.
- Sponge over the hand, close the coil with the larger flap over the smaller and overlapping, then a sandbag over the arm.
- Arm overhead: pad between the raised arm and the head, keep the hand and coil off the bore wall, and put the call bell in the other hand.
- What goes wrong, and the fix
- Spectral fat suppressionSPIR/SPAIR fat suppressionFat Sat/SPAIR fat suppression patchy between the fingers: re-tape to close the air gaps, or use DixonmDIXONDixon.
- Thumb tucked under: bring it into line, or you will need extra coronal coverage.
- Signal drop-off: the coil flaps are not overlapping.
- Patient cannot lie in the superman position: arm by the side, with pads between the arm and the body, the hand and the thigh, and the arm and the bore.
- Check on the first localisersurveylocalizer
- On the coronal localisersurveylocalizer the hand and wrist lie flat and straight, with all the joints in one plane.
- Good to know
- Air spaces against soft tissue make the local field uneven, which spoils chemically selective fat suppression; taping also immobilises the fingers. With the thumb adducted alongside the fingers, magic angle artefact in the thumb tendons is reduced. Some services image both hands together in the “prayer” position for inflammatory arthritis.
Explain it simply
The fingers are taped together so there is no air between them. Air next to skin upsets the scanner’s fat-removal trick, so taping gives cleaner pictures.
Why it matters: Patchy fat suppression can hide joint inflammation or mimic it.