Real-time guidance lets you see the target, the needle, and the structures to avoid (vessels, pleura, bowel, nerves) as the needle moves. This page covers the geometry of needle guidance, asepsis and safety, and the four workhorse procedure families: biopsy, drainage/aspiration, vascular access, and musculoskeletal/pain injections.
Related
On this page
Needle guidanceAsepsis, consent & safetyBiopsyDrainage & aspirationVascular accessMSK & painSourcesContent verified against SIR periprocedural coagulation consensus, AIUM vascular-access practice parameters, radiology society technique references and the interventional literature listed in the References. Educational summary only. Every procedure here requires a trained, credentialled operator; thresholds, consent and technique follow your local policy.
- Never advance a needle you cannot see: if the tip is lost, stop, pull back and re-align the beam until it reappears; out of plane, the bright dot may be shaft rather than tip, so track the tip dynamically.
- In-plane guidance keeps the whole needle and tip in view, which suits deep or high-risk targets; out-of-plane suits shallow vascular access if the tip is tracked; a needle is brightest when the beam meets it at 90°, so steep needles fade.
- Before the needle: confirm patient, procedure and side, consent and coagulation status against the procedure’s bleeding-risk category, map vessels along the whole trajectory with colour Doppler, and hold a time-out immediately before puncture.
- For vascular access: see the vein, confirm it is venous (compression and Doppler), puncture under real-time vision, confirm the wire is in the vein, then dilate; a dilator or catheter in an artery must not simply be removed.
- For paracentesis, the usual lower-quadrant approach is lateral to the rectus, with Doppler of the puncture site, to avoid the inferior epigastric artery; for thoracentesis, enter just above the rib below and never below the effusion.
Explain it simply
- Never push a needle on without seeing its tip. If you lose it, stop, pull back and adjust the probe until it shows. End-on, the bright dot may be shaft, not tip: keep finding the tip.
- Keeping the needle in the probe’s line shows all of it, tip included, which suits deep or risky targets; crossing the beam suits shallow vessels if you keep finding the tip. Steep needles show faintly.
- Before any needle, check the right patient, procedure and side, consent, and blood-clotting results for that procedure’s bleeding risk. Map blood vessels along the whole needle path with Doppler, and pause for a final team check.
- For a line: find the vein, prove it’s a vein by pressing and Doppler, needle it while watching, and see the wire inside before widening. Never just pull out a tube that has entered an artery.
- Draining belly fluid: the usual spot is low down, outside the front belly muscle, after a Doppler check to miss an artery. Draining chest fluid: go in just above a rib, never below the fluid.
A guide only: follow your departmental protocols and regional requirements.
Principles of needle guidance
Every ultrasound-guided puncture answers one question: where is my needle tip right now? The tip does the cutting and sampling and causes any injury, so tip control is the priority. There are two geometries for aligning the needle to the ultrasound beam (in-plane and out-of-plane), and the choice governs what you can see.1,2
In-plane (long-axis)
Needle aligned along the long axis of the probe, travelling within the imaging sheet. The entire needle including the tip is visualised as it advances: a continuous view of the tip, which many operators prefer for deep or high-risk targets (biopsy near a capsule, block near a nerve). The cost: it is technically harder to keep needle, transducer and target coplanar, and small drifts make the whole needle disappear.
Out-of-plane (short-axis)
Needle crosses the beam perpendicularly; the target sits as a round structure and the needle shows only as a bright dot. Faster to learn, good for shallow vascular access, and keeps the vessel and its neighbours in view. Danger: the dot may be shaft, not tip; advance the needle too far and the real tip is already past the target. Use dynamic tip tracking (walk the probe ahead, keep re-finding the tip).
Making the needle visible
Needle conspicuity depends on geometry and a few techniques:
- Angle of insonation is everything. A needle is brightest when the beam hits it at 90°. The steeper (more vertical) the needle, the worse the reflection back to the probe and the fainter the needle; deep targets that force a steep angle are the hardest to image.2,3
- Heel–toe / probe rocking: tilt (rock) the transducer to bring the beam perpendicular to the needle, restoring the bright shaft.
- Beam steering & needle-enhancement software: most machines can electronically steer the beam toward the needle (or overlay a needle-enhance algorithm) without moving the probe. In a laboratory study steering made a standard needle clearly visible at 40° but did not rescue it at 60° to 70°.3
- Echogenic needles: laser-etched/dimpled tips scatter sound back toward the transducer and are more visible than standard needles at steep angles, though no single design is clearly best; favoured for deep blocks and biopsies.3,28
- Hydro-location (hydro-dissection): inject a small bolus of saline/anaesthetic; the anechoic fluid flash confirms the true tip position and can open a safe plane away from a nerve or vessel.
- Jiggle / priming: a small in-and-out or stylet movement, or a flush, creates motion/colour that reveals the tip.
Free-hand vs needle guide
| Approach | How it works | Strengths | Trade-offs |
|---|---|---|---|
| Free-hand | Operator controls probe and needle independently; no attachment. | Maximum flexibility: adjust angle mid-pass, choose in- or out-of-plane freely; essential skill for MSK/blocks and complex targets. | Steeper learning curve; demands good hand–eye coordination. |
| Needle guide (bracket) | A clip-on guide fixes the needle to a predicted on-screen path. | Reproducible trajectory; helpful for deep, small or fixed targets (some thyroid/prostate/biopsy setups) and for trainees. | Fixed angle limits fine adjustment; adds a consumable; still requires tip vigilance. |
Asepsis, consent & safety
Beyond the image, the procedure depends on avoiding infection and avoidable bleeding, and on doing the right procedure on the right patient. Get the checklist right before the needle is opened.
Pre-procedure checklist
- Right patient, right procedure, right side/site: confirmed against the request and imaging.
- Valid indication & informed consent documented (benefits, risks, alternatives, who is performing).
- Coagulation status reviewed: INR/PT, platelets, and antithrombotic/anticoagulant medications, against the procedure’s bleeding-risk category.
- Relevant history: allergies (incl. local anaesthetic, chlorhexidine, latex), pregnancy, renal function if contrast/sedation, prior reactions.
- Fasting/sedation plan if required; IV access and monitoring available for deeper procedures.
- Pre-scan the target: confirm it, plan the trajectory, and map vessels/pleura/bowel/nerves to avoid.
- Sterile field prepared: skin antisepsis, sterile probe cover, sterile gel, drape.
- Kit & count: correct needle/catheter, specimen pots/fixative, dressings; sharps/specimen labelling ready.
- Team time-out (“stop moment”): verbalise patient, procedure, site, consent, allergies, coagulation immediately before the needle.
- Post-procedure plan: observation duration, positioning, discharge criteria and safety-net advice agreed.
Sterile technique
- Aseptic non-touch technique (ANTT): hand hygiene, skin antisepsis (chlorhexidine-alcohol usually preferred; allow to dry), and a sterile field sized to the procedure.
- Sterile probe cover + sterile gel: the transducer is not sterile; use a sterile single-use cover (with sterile gel inside for coupling and sterile gel/coupling outside). For deeper/longer procedures (e.g. central lines, drains) use a full-length sleeve and maximal barrier precautions.
- Probe reprocessing: for percutaneous procedures, guidelines differ: the ESR advises sterilisation or high-level disinfection plus a sterile cover, while the AIUM and an intersocietal statement (ACEP, AIUM, APIC, AVA, SHEA) accept cleaning and low-level disinfection when a sterile cover and sterile gel are used.25,26 Follow your local infection-control policy and the probe manufacturer’s instructions. Endocavity probes are semi-critical → high-level disinfection between patients (see the Safety & Bioeffects page).4
Coagulation checks
The SIR periprocedural consensus stratifies procedures by bleeding risk rather than applying one universal cut-off, and stresses individualised assessment.5 Representative (not prescriptive) thresholds:
| Bleeding-risk category | Example procedures | Illustrative INR guide | Illustrative platelet guide |
|---|---|---|---|
| Low risk | Paracentesis, thoracentesis, superficial aspiration, most diagnostic drains, tunnelled central venous catheters and ports | Correct if > ~2.0–3.0 | Transfuse if < ~20 ×10⁹/L |
| High risk | Solid-organ biopsy (liver, renal), deep/non-compressible sites | Target ≤ ~1.5–1.8 | Target ≥ ~50 ×10⁹/L |
Values are illustrative of the SIR 2019 framework5 and vary by procedure, guideline edition and patient; a 2026 Canadian guideline (CAR/CAIR) builds on it24. Always check the current guideline and your local policy. Paracentesis in particular has a very low major-bleeding rate even with abnormal coagulation, and routine correction/transfusion is often not required.5,23
Site selection & avoiding structures
- Colour/power Doppler before you puncture: map arteries and veins along the whole trajectory, not just at the target; the epigastric and intercostal vessels are classic avoidable hits.
- Shortest safe path that avoids lung/pleura, bowel/gas, major vessels and nerves; choose the window, then the angle.
- Respiration matters: pleura and diaphragm move; time the puncture and watch the sliding pleura for thoracic/upper-abdominal work.
- Compressible over non-compressible where a choice exists (relevant to vascular and biopsy site selection).
Consent & the time-out
Informed consent covers the indication, the realistic benefit, the specific risks (bleeding, infection, injury to adjacent structures, failure/non-diagnostic result, need for repeat), and alternatives including no procedure. A WHO-style time-out immediately before the needle (patient, procedure, site/side, consent, allergies, coagulation, kit ready) catches wrong-site and wrong-patient errors.
Post-procedure care
- Haemostasis & dressing; position for the site (e.g. biopsy-side down for some solid-organ biopsies per local protocol).
- Observation proportionate to risk: vitals, pain, the puncture site; post-thoracentesis imaging/observation for pneumothorax where indicated.
- Specimen handling: correct fixative/medium, labelled at the bedside, sent promptly.
- Documentation: operator, consent, technique, needle passes, immediate outcome/complications, and safety-net/return advice.
Complications
| Complication | Where it matters most | Recognition | Prevention / response |
|---|---|---|---|
| Bleeding / haematoma | Solid-organ biopsy, deep/non-compressible sites, vascular | Pain, falling Hb, expanding swelling, hypotension | Coag optimisation, Doppler planning, avoid capsule/vessels; observe, pressure, imaging, escalate/transfuse/embolise |
| Pneumothorax | Thoracentesis, lung/pleural & upper-abdominal biopsy, IJ/subclavian lines | Dyspnoea, chest pain, loss of pleural sliding on US | US pleural mapping, shortest path, respiration timing; O₂, observation, chest drain if large/symptomatic |
| Infection | Any breach; higher with drains/lines & endocavity work | Fever, site cellulitis, purulence, later abscess | Full aseptic technique, sterile cover/gel, probe reprocessing; antibiotics/drainage if established |
| Injury to adjacent structure | Bowel, nerve, artery, pleura, other organs | Depends on structure: pain, neuro deficit, bleeding, peritonism | Continuous tip visualisation, in-plane for high-risk targets, hydro-dissection; recognise early and manage per structure |
| Vasovagal / LA toxicity | Any awake procedure | Faint, bradycardia; LAST: perioral tingling, arrhythmia, seizure | Supine positioning, dose LA to weight, aspirate before injecting; LAST → stop, ABC, lipid emulsion protocol18,36,37 |
| Non-diagnostic / failed sampling | Biopsy & FNA | Inadequate specimen at pathology/adequacy check | Target the solid/viable part, adequate passes, on-site adequacy where available; repeat if needed |
Biopsy
In ultrasound-guided biopsy, the needle path, the target and the danger structures are all in view. The two sampling philosophies are fine-needle aspiration (FNA) for cytology and core-needle biopsy (CNB) for histology.
FNA (fine-needle aspiration)
Thin needle (e.g. 23–27 G), to-and-fro/rotary sampling, yields cells for cytology. Low complication rate, minimal bleeding. Ideal for thyroid nodules and lymph nodes. Limitation: no tissue architecture; cannot always distinguish e.g. follicular lesions.
CNB (core-needle biopsy)
Larger cutting/spring-loaded needle (e.g. 14–18 G) takes a tissue core for histology: architecture, immunohistochemistry, receptor status. Standard for breast lesions and solid-organ (liver/renal) work. Higher yield, slightly higher bleeding risk.
Common targets & technique notes
| Target | Usual method | Technique notes |
|---|---|---|
| Thyroid nodule | FNA (25 G common) | Real-time guidance; ~3–5 passes typical; to-and-fro over 5–10 s; sample solid/hypoechoic components; report by Bethesda; on-site adequacy improves yield.7 |
| Breast lesion | Core (14 G) ± vacuum-assisted | Multiple cores through the solid part; parallel-to-chest-wall approach to avoid pleura; clip placement for later localisation. |
| Liver (focal or diffuse) | Core (16–18 G) | High-risk bleeding site: optimise coagulation; choose a path with intervening normal liver (“tract of parenchyma”); avoid large vessels/dilated ducts; post-biopsy positioning & observation. |
| Renal / renal mass | Core (16–18 G) | High-risk site; coaxial technique common; target viable (non-necrotic) tumour; avoid the hilum; observe for haematuria/perinephric haematoma. |
| Lymph node | FNA and/or core | Target cortex, avoid hilar vessels (Doppler first); core preferred where lymphoma is possible (needs architecture). |
Technique principles that cut across all biopsies
- Sample the viable target, not the middle: necrotic/cystic centres give non-diagnostic results; aim for the solid, vascularised (but not the vessel) periphery.
- Capsule avoidance: where possible traverse a rim of normal parenchyma before entering a mass, and avoid puncturing the organ capsule at a tangent; a straight tract seals better and bleeds less (classic for liver/kidney).
- Number of passes: enough for a diagnostic sample, no more; each pass adds bleeding/seeding risk. FNA thyroid ~3–5; core lesions a few good cores. Fewer, better-targeted passes beat many blind ones.7
- On-site adequacy (ROSE): a cytotechnologist/pathologist checking the smear at the bedside raises the diagnostic rate and reduces repeat visits. It is used widely for thyroid and node FNA.7
- Tract considerations & seeding: for certain tumours a coaxial technique keeps passes on one tract and can allow tract management; discuss seeding risk where relevant (e.g. some HCC pathways).
- Continuous tip vision: in-plane long-axis is preferred so the cutting tip is watched into and out of the target.
Drainage & aspiration
Fluid collections are the natural home of ultrasound guidance: the target is anechoic and obvious, the needle path is short, and real-time imaging keeps the tip out of bowel, lung and vessels. Aspiration removes fluid with a needle/syringe; drainage leaves a catheter for ongoing output.
The common procedures
| Procedure | Target | Key points |
|---|---|---|
| Paracentesis | Ascites | Usually lower-quadrant approach, lateral to the rectus (avoid the inferior epigastric artery; map with Doppler); a Z-track entry may limit leakage, though evidence for it is limited; low bleeding risk even with abnormal coagulation.5,23,35 |
| Thoracentesis | Pleural effusion | Scan, mark and puncture with the patient in the same position; enter directly above a rib, preferably in the triangle of safety, and avoid a posterior approach near the spine, where the intercostal artery may lie unprotected in the space; confirm effusion depth and lung/diaphragm position; watch for pneumothorax (loss of sliding).8,29,30,34 |
| Abscess drainage | Infected collection | Catheter drainage (Seldinger or trocar); choose a safe window; send fluid for micro; large/complex collections often need a pigtail left in situ. |
| Joint aspiration / injection | Effusion, crystal arthropathy, therapeutic injection | Confirm intra-articular position; aspirate for cell count/crystals/culture; strict asepsis (septic-joint concern); inject under vision. |
| Cyst aspiration | Symptomatic / diagnostic cyst | Simple cysts aspirate readily; sample for cytology if indicated; some (e.g. breast, thyroid) recur and may need re-aspiration or sclerosis. |
Seldinger vs trocar
Seldinger technique
Needle → guidewire → dilator(s) if the catheter needs them → catheter over the wire. More steps but very controlled, suited to deep, small or awkward collections; the wire keeps access throughout. Usually preferred over the trocar technique for image-guided drains; a 2025 review attributes less pain, organ injury and bleeding to it, though formal guidelines are lacking.33
Trocar technique
Catheter mounted on a stiff stylet advanced directly into the collection in one motion. Fast and fewer steps for large, superficial, easily-accessed collections, but less controlled, so reserved for big obvious targets.
Catheter selection
- Fluid viscosity drives calibre: thin serous fluid drains through small pigtails (e.g. 8–10 Fr); thick pus/empyema/haematoma usually needs a larger bore to avoid blockage. There is no standard size guideline, and choice varies between operators.33
- Locking pigtail catheters resist dislodgement for collections that need to stay drained; simple aspiration needs only a needle.
- Diagnostic vs therapeutic: a one-off tap for sampling differs from a drain left for days; plan flushing, output monitoring and removal criteria for the latter.
Vascular access
Ultrasound guidance for vascular access is now a standard of care; it raises first-pass success and cuts complications for central lines and difficult peripheral access alike.9 The two big families are central venous access (classically the internal jugular vein, IJV) and peripheral/PICC access.
Dynamic vs static guidance
Dynamic (real-time)
The needle is advanced while imaging, tip watched into the vein. The recommended default: you see the puncture happen and avoid the back wall and the artery. Usually out-of-plane (short axis) for IJV; long-axis in-plane gives continuous tip view for the experienced.
Static (locate-and-mark)
Ultrasound is used to find and mark the vein, then the probe is put down and the puncture done blind. Better than pure landmark, but inferior to real-time; reserved for when real-time is impractical.
Confirming vein vs artery before you dilate
| Feature | Vein | Artery |
|---|---|---|
| Compressibility | Compresses easily with light probe pressure | Non-compressible / minimally compressible |
| Pulsatility | Non-pulsatile (may vary with respiration) | Pulsatile |
| Shape / wall | Thin-walled, often oval, collapses | Round, thicker wall, holds shape |
| Doppler | Low-velocity, phasic/venous waveform | High-velocity, pulsatile arterial waveform |
Colour/pulsed Doppler and the compression test together confirm the venous target. On accidental arterial puncture with only a small needle, hold pressure; if a dilator/catheter has entered an artery, do not simply remove it; get vascular/surgical advice.
Avoiding the posterior wall & other pitfalls
- Posterior-wall puncture: a common cannulation error; advancing too far spears the back wall (and beyond it the artery/pleura). Watch the tip, and use short controlled advances with continuous imaging (dynamic tip tracking out-of-plane, or long-axis in-plane).
- Confirm the wire in the vein before dilating; imaging the guidewire within the vein before dilating helps prevent arterial dilatation, a serious access complication.
- Tip position: for central lines confirm catheter-tip position (e.g. cavoatrial junction) by the unit’s protocol; malposition and arrhythmia are recognised issues.
- Site-specific risks: IJV (carotid puncture, pneumothorax with lower approaches); subclavian (higher pneumothorax); femoral (infection/thrombosis). Maximal barrier precautions for all central lines.
- PICC / peripheral: upper-arm basilic/brachial veins under ultrasound for difficult access; measure depth and diameter; avoid the brachial artery and median nerve nearby.
Ultrasound-guided peripheral IV cannulation (USGPIV)
Peripheral IV insertion is one of the most common invasive procedures in hospital, and ultrasound helps when landmarks fail. In difficult IV access (DIVA) patients (obesity, oedema, chemotherapy, IV drug use, chronic disease, dark or fragile veins, paediatrics), ultrasound guidance raises the success rate of cannulation versus landmark technique (in one meta-analysis, 81% vs 70% overall success; odds ratio about 2.5) and reduces escalation to central lines.19,20 Escalate to ultrasound after 1–2 failed landmark attempts, or first-line in predicted DIVA (e.g. a positive A-DIVA score: visible/palpable vein absent, history of difficult access, vein <3 mm).20
Setup & vein selection
Equipment
High-frequency linear probe (≥10 MHz), shallow preset (2–3 cm depth), tourniquet, single-use sterile gel and probe cover/dressing per local policy, and, critically, a long catheter (≥45 mm) for veins deeper than ~0.8 cm. Standard-length cannulae in deep veins fail early.21
The ideal vein
Forearm first (cephalic, median antebrachial), then antecubital, then upper-arm basilic/cephalic. Target diameter ≥0.4 cm and depth ≤1.5 cm where possible; trace the vein to confirm a straight, valve-free segment. Avoid the brachial vein when alternatives exist; the artery and median nerve travel with it.9,21
Catheter-to-vein ratio
Keep the catheter ≤45% of vein diameter (roughly 1:3) to preserve flow around the cannula and reduce thrombosis/phlebitis; aim for a long length inside the vein: one study found catheters with at least 65% of their length inside the vein lasted longer, and short intraluminal length is a recognised cause of early failure and infiltration.21,22
Technique: short axis vs long axis
| Short axis / out-of-plane (default) | Long axis / in-plane | |
|---|---|---|
| View | Vein as a circle; needle crosses the beam as a dot | Whole shaft + tip visible continuously |
| Strength | Easier to learn; keeps neighbouring artery/nerve in view | Best tip control; avoids posterior wall |
| Weakness | The “dot” may be shaft, not tip (posterior-wall puncture risk) | Harder to keep thin veins in a 1-mm-wide beam |
| Key habit | Dynamic tip tracking: advance needle a few mm → slide probe until tip reappears → repeat (“creep/leapfrog”) | Keep shaft fully in-plane; heel-toe the probe |
Step-by-step (short axis): tourniquet → survey and choose the vein → centre it on screen → puncture at ~30–45° a few mm behind the probe, aiming for the beam → find the tip as a bright dot with ring-down → track the tip to the anterior wall → pop through (wall tents then gives) → drop the angle, confirm the tip intraluminal → advance needle a few mm further in-vein before threading the catheter (prevents extraluminal threading) → thread, release tourniquet, flush.
Confirming placement & complications
- Confirm: tip and catheter visible in-lumen in two planes; brisk saline flush shows intraluminal echogenic swirl (“bubble test”) with no perivenous fluid.
- Early failure/infiltration: the commonest problem; usually short intraluminal catheter length or a too-deep vein with a standard cannula. Fix with long catheters and the ≥65% rule.21
- Arterial puncture / nerve injury: know the brachial artery and median nerve before needling the medial arm; paraesthesia = stop and withdraw.
- Infection: single-use gel, disinfected probe, sterile cover/semipermeable dressing over the probe face per INS/AIUM guidance; gel must never contact the puncture site.4,22
- Document: ultrasound use, vein, depth, catheter length/gauge, attempts; USGPIV counts as an ultrasound-guided procedure in most policies.
Musculoskeletal & pain intervention
Ultrasound suits musculoskeletal injections and blocks: superficial targets, high soft-tissue resolution, no radiation, and the ability to watch injectate spread in real time. Systematic reviews generally find ultrasound-guided injections more accurate than landmark-guided ones, though not at every site (for example, similar accuracy for the subacromial space in one meta-analysis), and effects on pain and function vary.27
Joint & bursa injections
- Confirm the compartment: image the effusion/recess and place the tip intra-articularly or intra-bursally under vision; injectate should flow into the space, not the soft tissue.
- Therapeutic agents (corticosteroid ± local anaesthetic; viscosupplements) are injected once position is confirmed; strict asepsis given the septic-joint concern.
- Common sites: shoulder (glenohumeral, subacromial-subdeltoid bursa), hip (deep, guidance especially valuable), knee, small joints, ganglia.
Tendon procedures
Calcific tendinopathy: barbotage / lavage
Ultrasound-guided percutaneous needle aspiration and lavage (“barbotage”) treats rotator-cuff (esp. supraspinatus) calcific deposits. After local anaesthesia and a subacromial-bursal injection, the deposit is punctured (e.g. an 18 G needle) and repeatedly flushed with saline so dissolved calcium refluxes into the syringe. Soft, resorptive-phase deposits (well-demarcated, hyperechoic, weak shadow) respond best.10,11
PRP / tendon needling
Platelet-rich plasma injection and dry needling/tenotomy for chronic tendinopathy are placed under ultrasound at the pathological tendon segment. Evidence varies by tendon and indication; technique emphasises accurate intratendinous placement and post-procedure load management.
Nerve blocks & regional anaesthesia
Ultrasound-guided regional anaesthesia lets you see the nerve, the needle and the local-anaesthetic spread around (not into) the nerve, improving success and reducing dose and complications versus landmark/paraesthesia techniques.12
- Tip in view: in-plane and out-of-plane approaches are both used for blocks, and recommendations from the German Society of Anaesthesiology and Intensive Care Medicine (DGAI) rate them as equally safe; with either, the tip must be seen relative to the nerve, directly or indirectly, and the injection must be seen.38
- Hydro-dissection / hydro-location: a test bolus confirms tip position and opens a plane around the nerve; watch the injectate spread around the nerve rather than into it, and do not inject if it needs high pressure.12,38
- Common blocks: interscalene/supraclavicular (brachial plexus), femoral/adductor-canal, popliteal sciatic, and fascial-plane blocks (e.g. TAP, erector spinae); landmarks and sonoanatomy differ for each.
Never inject against high resistance or into a nerve. intraneural injection can injure the nerve, and injury is most severe when the injection is intrafascicular; pain/paraesthesia on injection means stop and reposition.38,39,40 Watch for local-anaesthetic systemic toxicity (LAST): dose to weight, aspirate before injecting, inject incrementally, and have a lipid-emulsion protocol available.18,36,37 Steroid injections carry their own cautions (post-injection flare, skin/fat atrophy, tendon-rupture concern with intratendinous steroid, glycaemic effects).
Sources
Sources (40)
40 sources listed
- Franco-Sadud R, Schnobrich D, Mathews BK, et al. Recommendations on the use of ultrasound guidance for central and peripheral vascular access in adults: a position statement of the Society of Hospital Medicine. J Hosp Med 2019;14(9):E1–E22. doi:10.12788/jhm.3287
- Chapman GA, Johnson D, Bodenham AR. Visualisation of needle position using ultrasonography. Anaesthesia 2006;61(2):148–158. (In-plane/out-of-plane; angle of insonation.)
- Uppal V, Sondekoppam RV, Ganapathy S. Effect of beam steering on the visibility of echogenic and non-echogenic needles: a laboratory study. Can J Anaesth 2014;61(10):909–915. doi:10.1007/s12630-014-0207-9
- Nyhsen CM, Humphreys H, Koerner RJ, et al. Infection prevention and control in ultrasound: best-practice recommendations (ESR Ultrasound Working Group). Insights Imaging 2017;8:523–535. (Sterile cover, Spaulding, probe reprocessing.)
- Patel IJ, Rahim S, Davidson JC, et al. SIR Consensus Guidelines for the Periprocedural Management of Thrombotic and Bleeding Risk in Patients Undergoing Percutaneous Image-Guided Interventions — Part II. J Vasc Interv Radiol 2019;30(8):1168–1184.e1. (Low- vs high-risk categories; INR/platelet thresholds; antithrombotic management.)
- DesRoche C, Callum J, Scholey A, et al. Platelet and INR thresholds and bleeding risk in ultrasound guided percutaneous liver biopsy: a before-after implementation of the 2019 Society of Interventional Radiology guidelines. Can Assoc Radiol J 2024;75(4):931–938. (Liver biopsy only: bleeding before and after adopting the SIR 2019 thresholds.)
- Kim MJ, Kim EK, Park SI, et al. US-guided fine-needle aspiration of thyroid nodules: indications, techniques, results. RadioGraphics 2008;28(7):1869–1886. (Passes, technique, Bethesda adequacy, ROSE.)
- Dancel R, Schnobrich D, Puri N, et al. Recommendations on the use of ultrasound guidance for adult thoracentesis: a position statement of the Society of Hospital Medicine. J Hosp Med 2018;13(2):126–135. doi:10.12788/jhm.2940
- American Institute of Ultrasound in Medicine. AIUM Practice Parameter for the Use of Ultrasound to Guide Vascular Access Procedures. J Ultrasound Med 2019;38(3):E4–E18. (Dynamic vs static; vein confirmation; posterior-wall avoidance.)
- del Cura JL, Torre I, Zabala R, et al. Sonographically guided percutaneous needle lavage in calcific tendinitis of the shoulder: short- and long-term results. AJR Am J Roentgenol 2007;189(3):W128–W134. (Barbotage technique & outcomes.)
- Louwerens JKG, Sierevelt IN, van Noort A, van den Bekerom MPJ. The role of ultrasound-guided percutaneous needle aspiration and lavage (barbotage) in the treatment of calcific tendinitis. Eur J Radiol 2015;84(11). (Patient selection; deposit consistency.)
- Marhofer P, Harrop-Griffiths W, Kettner SC, Kirchmair L. Fifteen years of ultrasound guidance in regional anaesthesia: Part 1. Br J Anaesth 2010;104(5):538–546. (Nerve visualisation, LA spread, in-plane technique.)
- Society of Interventional Radiology / CIRSE. Standards of Practice for image-guided biopsy and drainage procedures. CIRSE. (Procedure standards, consent, technique.)
- American College of Radiology. ACR–SIR Practice Parameters for image-guided percutaneous needle biopsy and fluid drainage. ACR.
- Aithal GP, Palaniyappan N, China L, et al. Guidelines on the management of ascites in cirrhosis. Gut 2021;70(1):9–29. doi:10.1136/gutjnl-2020-321790
- Seldinger SI. Catheter replacement of the needle in percutaneous arteriography; a new technique. Acta Radiol 1953;39(5):368–376. doi:10.3109/00016925309136722
- Gervais DA, Sabharwal T (eds). Interventional Radiology Procedures in Biopsy and Drainage. Springer. (Catheter selection, abscess drainage, Seldinger/trocar.)
- Neal JM, Barrington MJ, Fettiplace MR, et al. The Third American Society of Regional Anesthesia and Pain Medicine practice advisory on local anesthetic systemic toxicity: executive summary 2017. Reg Anesth Pain Med 2018;43(2):113–123. doi:10.1097/AAP.0000000000000720
- Gottlieb M, Sundaram T, Holladay D, et al. Ultrasound-guided peripheral intravenous line placement: a narrative review of evidence-based best practices. West J Emerg Med 2017;18(6):1047–1054. (USGPIV vs landmark success in DIVA.)
- van Loon FHJ, Buise MP, Claassen JJF, et al. Comparison of ultrasound guidance with palpation and direct visualisation for peripheral vein cannulation: systematic review and meta-analysis. Br J Anaesth 2018;121(2):358–366. (Plus the A-DIVA prediction scale, van Loon et al. Medicine 2016.)
- Bahl A, Hijazi M, Chen NW, et al. Ultralong versus standard long peripheral intravenous catheters: a randomized controlled trial of ultrasonographically guided catheter survival. Ann Emerg Med 2020;76(2):134–142. (Long catheters, intraluminal-length rule; see also Pandurangadu et al. Emerg Med J 2018 on catheter-in-vein proportion.)
- Infusion Nurses Society. Infusion Therapy Standards of Practice, 9th ed. J Infus Nurs 2024;47(1S). (Vessel-health preservation, catheter-to-vein ratio, aseptic USGPIV insertion.)
- Biggins SW, Angeli P, Garcia-Tsao G, et al. Diagnosis, evaluation, and management of ascites, spontaneous bacterial peritonitis and hepatorenal syndrome: 2021 practice guidance by the American Association for the Study of Liver Diseases. Hepatology 2021;74(2):1014–1048. (Paracentesis without routine plasma or platelet transfusion.)
- Harper K, Hurrell C, Gupta A, et al. CAR/CAIR practice guidelines: periprocedural management of patient bleeding risk. Can Assoc Radiol J 2026. (Canadian guideline building on SIR 2019.)
- ACEP, AIUM, APIC, AVA, SHEA. Disinfection of ultrasound transducers used for percutaneous procedures: intersocietal position statement. J Ultrasound Med 2021;40(5):895–897. (Low-level disinfection with a sterile cover and sterile gel.)
- American Institute of Ultrasound in Medicine. Guidelines for cleaning and preparing external- and internal-use ultrasound transducers and equipment between patients, as well as safe handling and use of ultrasound coupling gel (revised 2025).
- Shen PC, Lin TY, Wu WT, Özçakar L, Chang KV. Comparison of ultrasound- vs. landmark-guided injections for musculoskeletal pain: an umbrella review. J Rehabil Med 2024;56. (Accuracy and outcomes by site.)
- Hovgesen CH, Wilhjelm JE, Vilmann P, et al. Echogenic surface enhancements for improving needle visualization in ultrasound: a PRISMA systematic review. J Ultrasound Med 2022;41(2):311–325. doi:10.1002/jum.15713
- Gordon CE, Feller-Kopman D, Balk EM, et al. Pneumothorax following thoracentesis: a systematic review and meta-analysis. Arch Intern Med 2010;170(4):332–339. doi:10.1001/archinternmed.2009.548
- Helm EJ, Rahman NM, Talakoub O, et al. Course and variation of the intercostal artery by CT scan. Chest 2013;143(3):634–639. doi:10.1378/chest.12-1285
- Cho J, Jensen TP, Reierson K, et al. Recommendations on the use of ultrasound guidance for adult abdominal paracentesis: a position statement of the Society of Hospital Medicine. J Hosp Med 2019;14:E7–E15. doi:10.12788/jhm.3095
- Le Saint-Grant A, Taylor A, Varsou O, et al. Arterial anatomy of the anterior abdominal wall: ultrasound evaluation as a real-time guide to percutaneous instrumentation. Clin Anat 2021;34(1):5–10. doi:10.1002/ca.23578
- Stevens C, Scott D, Ramesh P, et al. The evolution of percutaneous abdominal abscess drainage: a review. Medicine (Baltimore) 2025;104(15):e41799. doi:10.1097/MD.0000000000041799
- Asciak R, Bedawi EO, Bhatnagar R, et al. British Thoracic Society Clinical Statement on pleural procedures. Thorax 2023;78(Suppl 3):s43–s68. doi:10.1136/thorax-2022-219371
- Bartal C, Sikuler E, Tsenter P, et al. Proposed clinical practice guidance for large-volume abdominal and pleural paracentesis with emphasis on coagulopathy management. J Clin Med 2025;14(23):8287. doi:10.3390/jcm14238287
- Neal JM, Neal EJ, Weinberg GL. American Society of Regional Anesthesia and Pain Medicine local anesthetic systemic toxicity checklist: 2020 version. Reg Anesth Pain Med 2021;46(1):81–82. doi:10.1136/rapm-2020-101986
- El-Boghdadly K, Pawa A, Chin KJ. Local anesthetic systemic toxicity: current perspectives. Local Reg Anesth 2018;11:35–44. doi:10.2147/LRA.S154512
- Steinfeldt T, Schwemmer U, Volk T, et al. Nerve localization for peripheral regional anesthesia. Recommendations of the German Society of Anaesthesiology and Intensive Care Medicine. Anaesthesist 2014;63(7):597–602. doi:10.1007/s00101-014-2343-6
- Sondekoppam RV, Tsui BC. Factors associated with risk of neurologic complications after peripheral nerve blocks: a systematic review. Anesth Analg 2017;124(2):645–660. doi:10.1213/ANE.0000000000001804
- Brull R, Hadzic A, Reina MA, et al. Pathophysiology and etiology of nerve injury following peripheral nerve blockade. Reg Anesth Pain Med 2015;40(5):479–490. doi:10.1097/AAP.0000000000000125
This page is an educational summary for imaging professionals and trainees. It is not clinical, legal or regulatory advice and does not replace supervised training, credentialling, national society guidelines, employer procedures, local infection-control policy, or the device manufacturer’s instructions for use. Coagulation thresholds, consent requirements, sterile standards and complication management are periodically revised and vary by procedure, patient and jurisdiction. Always confirm the current primary source and local policy before relying on any value in practice. Ultrasound-guided procedures must only be performed by appropriately trained, credentialled operators. © High Yield Imaging.