MRI high-yield summary
One-page cram sheet distilling the essentials from every High Yield Imaging MRI reference: physics, artifacts, contrast, safety, search patterns, and reporting. For revision; not a substitute for the full guides or local policy.
Related
On this page
Sequence physicsVendor decoderArtifactsGadolinium contrastMR safetySearch patternsReporting systemsMust-not-miss casesThe 10-second troubleshooting reflexesSequence physics
- TR controls T1 weighting (short TR = more T1); TE controls T2 (long TE = more T2).
- T1w = short TR / short TE. T2w = long TR / long TE. PD = long TR / short TE.
- Larmor: 42.58 MHz/T → 63.9 MHz @1.5 T, 127.7 MHz @3 T.
- SNR ∝ voxel volume × √(NEX × phase-encoding steps ÷ bandwidth); rises with field strength, falls with bandwidth.
- STIR TI ≈ 0.69 × T1(fat) to null fat; B0-insensitive → best near metal.
- Fat & water opposed-phase TE ≈ 2.2 ms @1.5 T (in-phase ≈ 4.4 ms).
GRE/EPI = fast but susceptibility-prone; SE/FSE = robust to susceptibility.
Vendor decoder
| Generic | Siemens | GE | Philips |
|---|---|---|---|
| Fast SE | TSE | FSE | TSE |
| SS-FSE | HASTE | SSFSE | SShTSE |
| Spoiled GRE | FLASH | SPGR | T1-FFE |
| Balanced SSFP | TrueFISP | FIESTA | bFFE |
| 3D T1 GRE | MPRAGE | BRAVO | 3D TFE |
Same physics, different trade names.
Artifacts
- Phase-direction: motion/flow ghosts, wrap-around, Gibbs → swap phase/frequency to move off ROI.
- Frequency-direction: chemical shift type 1 → raise bandwidth.
- Chemical shift type 2 (India-ink): opposed-phase GRE; used to prove microscopic fat.
- Susceptibility/metal: SE over GRE, short TE, high BW, STIR not spectral fat-sat.
- Gibbs: pseudo-syrinx in cord; don’t call a real one.
- Zipper/herringbone: RF/hardware; check door, shielding, spikes.
3 T amplifies chemical shift, susceptibility & dielectric shading.
Gadolinium contrast
- Standard dose 0.1 mmol/kg.
- ACR Group I (linear, e.g. gadodiamide) = highest NSF risk → contraindicated on dialysis or with eGFR<30; avoid in AKI.
- Group II (a named list: gadobutrol, gadoteridol, gadoterate, gadobenate, gadoxetate) = few/no unconfounded NSF cases → usable at any eGFR. Gadopiclenol is provisional (Group II*): local practice may treat it as Group II or III.
- Pregnancy: only if essential. Lactation: may continue breastfeeding per ACR (<0.04% excreted); NZ data sheets for MultiHance, Omniscan and Primovist advise a 24-hour pause; informed choice (RANZCR).
- Prior allergic-like reaction: guidelines differ (ACR: a different agent, with premedication considered; ESUR: allergy referral and a different agent); follow local policy; recognise extravasation (elevate, monitor for compartment syndrome).
Retention greater with linear agents; no proven clinical harm with normal renal function.
MR safety
- The magnet is always on. Ferromagnetic projectile = the lethal hazard.
- Zones I–IV; Zone IV = magnet room. The controlled access area is bounded by a fringe-field contour marked on the site plan: 0.9 mT (9 G) per IEC 60601-2-33 Ed 4.0 (2022) and the ACR Manual on MR Safety (2026); the older 0.5 mT (5 G) contour lies further out and remains conservative and widely used. Know which one your site uses.
- Cardiac arrest in Zone IV: remove the patient; never bring a crash cart/O₂ cylinder in.
- Quench: everyone out at once; if venting fails, cold helium displaces oxygen, so keep low; no re-entry until a qualified person confirms the field has fallen.
- Screen for cardiac devices, cochlear implants, aneurysm clips, neurostimulators, orbital metal (metal injury to the eye: orbit screening before MRI to ACR or RANZCR criteria).
- Prevent RF burns: no skin-to-skin loops, pad cables, ear protection for acoustic noise.
SAR ∝ B0²; more heating at 3 T.
Search patterns
- Always systematic; beware satisfaction of search (stop after first finding).
- Brain: DWI/ADC every time; check skull base, IACs, pituitary, vessels, sinuses.
- Spine: cord signal, conus level, every disc, and glance kidneys/aorta on sagittals.
- Prostate: scan the skeleton on T1 + DWI for mets.
- Knee: menisci, cruciates, cartilage, marrow oedema, extensor mechanism.
Check the corners of every image last.
Reporting systems
- PI-RADS v2.1: PZ driven by DWI, TZ driven by T2; category 1–5.
- LI-RADS v2018: non-rim APHE plus size-dependent additional features (washout, capsule, threshold growth) → LR-5; LR-M = probably malignant non-HCC.
- BI-RADS: 0–6; assess background enhancement, mass vs non-mass, kinetics.
- Rectal (ESGAR): mrCRM ≤1 mm = threatened margin; report EMVI, T/N stage, tumour height.
- MS (2024 McDonald): lesions in at least 2 of 5 locations (optic nerve added); with a typical presentation, 4 or more can be enough alone; otherwise add dissemination in time, CSF oligoclonal bands or kappa free light chains, or the central vein sign.
Must-not-miss cases
- Stroke: DWI bright + ADC dark; DWI-FLAIR mismatch dates it <4.5 h.
- Cord compression / cauda equina: emergency; assess conus & canal.
- Bucket-handle meniscus: double-PCL sign.
- HCC: arterial hyperenhancement + washout (LR-5).
- Pituitary apoplexy: sudden headache + visual loss + haemorrhagic mass.
MS: Dawson’s fingers, periventricular/callosal lesions.
The 10-second troubleshooting reflexes
- Artifact is geometric and unrelated to anatomy → hardware/RF (door, shield, spike).
- Artifact changes with breathing/pulsation → physiologic (coach, gate, sat bands, swap phase).
- Artifact tied to metal/air/interface or worse at 3 T → physics (bandwidth, TE, sequence family, fat-sat method, shim).
- Fat suppression patchy → use STIR or Dixon; shim; centre at isocentre.
- Poor eGFR + need contrast → reach for an ACR Group II agent.
- Anything ferromagnetic near the bore → stop; the field never switches off.
Distilled from the High Yield Imaging MRI reference set: Artifact Atlas · Sequence Physics · Contrast Decision Guide · Search Patterns · Screening & Positioning · Reporting Templates · Case Library · Question Bank. Educational revision aid only. Confirm details against current guideline editions and local protocols. Sources: Ridgway 2010 and Biglands 2012 (J Cardiovasc Magn Reson, MR physics); ACR Manual on Contrast Media (2026); ACR Manual on MR Safety (2026); Huang 2015 and Del Grande 2014 (RadioGraphics, artefacts and fat suppression); ACR PI-RADS/LI-RADS/BI-RADS; ESGAR.
More in Physics and foundations
Next in Physics and foundations: MRI trainee manual