MRI for allied health and referrers
Plain-clinical guides for the people around the scanner: referrers choosing a test, therapists reading reports, oncology teams, ward staff and sonographers.
Which scan when: MRI vs CT vs ultrasound
The right first test depends on the tissue, the urgency, and the radiation/contrast trade-off. MRI wins on soft-tissue contrast and carries no ionising radiation, but it is slower, less available, and gated by safety screening.
| Presentation | Usual first-line | Why |
|---|---|---|
| Acute stroke | CT (then MRI) | CT excludes bleed fast; MRI-DWI for early infarct/posterior fossa |
| Acute head injury | CT | Speed, bone, acute haemorrhage |
| Suspected cord compression | MRI (urgent) | Only MRI shows cord & marrow directly |
| Soft-tissue mass / internal derangement of joint | MRI (US for superficial) | Soft-tissue contrast; US good for tendons/effusions at bedside |
| Renal colic | CT (low-dose) | Stones; MRI poor for calcium |
| Liver/biliary characterisation | MRI / MRCP | Lesion characterisation, ducts without contrast |
| Prostate assessment | Multiparametric MRI | Before biopsy; PI-RADS |
| Suspected DVT | Ultrasound | Fast, bedside, no radiation |
An interactive version of this decision aid (pick a presenting complaint and get the recommended modality with the reasoning) is available as a standalone tool.
Reading MSK MRI reports for physios, chiros & podiatrists
You do not need to read the images, but decoding the report changes how you treat. Two principles first: signal is not symptom (many “findings” are asymptomatic and age-related), and the sequence tells you what the signal means.
What the sequences are telling you
| Phrase in report | Plain meaning |
|---|---|
| High signal on STIR / T2 fat-sat | Water: oedema, active/inflammatory or acute change (e.g. bone-marrow oedema, muscle strain) |
| Low signal on T1 in marrow | Something replacing normal fatty marrow (oedema, infiltration); correlate clinically |
| Intrasubstance high signal not reaching surface | Degenerative tendon/meniscus change, often not a full tear |
| Full-thickness / surface-reaching signal | Actual tear |
| Fluid signal in bursa/joint | Effusion/bursitis: common, interpret with symptoms |
MRI in oncology & radiotherapy
MRI’s soft-tissue contrast makes it central to modern radiotherapy, for defining the target and for delivering treatment.
Target delineation
MRI is co-registered with the planning CT to draw the tumour (GTV) and organs at risk far more accurately than CT alone, especially in brain, head & neck, prostate, cervix and sarcoma. CT still provides the electron density needed for dose calculation.
MR-LINAC
An MR-LINAC combines a linear accelerator with an onboard MRI, so the team images the tumour in real time during each fraction. That enables daily plan adaptation to the anatomy of the day and gated delivery that tracks motion. This is valuable for pancreas, liver, prostate and other mobile targets, supporting tighter margins.
Inpatient MRI safety for ward & ICU staff
Sending a sick inpatient to MRI is a safety-critical handoff. The magnet is always on. Serious incidents include ferromagnetic objects becoming projectiles and burns from monitoring leads.
Before the patient leaves the ward
- Screen the patient: implants, pacemaker/ICD, aneurysm clips, cochlear implants, recent stents, metallic foreign bodies, pregnancy.
- Screen the equipment: only MR Conditional pumps, monitors and oxygen cylinders enter the room; standard ones are projectiles.
- Lines & patches: remove or check external pacing wires and unnecessary lines; flag medication patches with metallic backing (burn risk): removal is reviewed by a Level 2 MR Physician, with the prescriber for an important drug, and needs a plan to replace the dose.
- Monitoring: use MR Conditional ECG/SpO2; avoid coiled cables against skin (RF burns).
MRI concepts for sonographers & cross-training techs
If you already think in acoustic impedance and Doppler, several MRI ideas map across cleanly, and a few will trip you up.
Concepts that transfer
- Contrast is tissue-property-driven: as echogenicity reflects impedance mismatch, MRI signal reflects T1/T2 relaxation and proton density; you choose a sequence to weight one.
- Fluid behaves predictably: simple fluid is bright on T2 (like anechoic-but-through-transmission intuition) and dark on T1.
- Motion & flow: flow voids and phase-contrast are MRI’s Doppler analogues.
What is different
- No real-time probe pressure or angle; planning is done up front with slices and sequences.
- Safety is dominated by the magnetic field, not thermal/mechanical index.
- Acquisition is far slower; motion is a bigger enemy.
Educational resource for healthcare professionals. Guidance is general and must be applied within local protocols and MR-safety governance; the referring/attending clinician and MR-safety officer retain responsibility for individual decisions.
More in Running the department
Where next: MRI question bank sampler
Educational reference for imaging professionals. It does not replace local policy, manufacturer labelling or clinical judgement.