Ultrasound question bank

Ultrasound question bank

Fourteen board-style single-best-answer questions spanning physics, artifacts, Doppler, abdominal, obstetric, vascular, small parts and safety. Written in the style of ARDMS (SPI/RVT/AB/OB-GYN) and Sonography Canada exams, and useful for ASAR- and CASE-accredited course assessments.

Related
How to use: read the stem, then click the option you think is correct. The card immediately turns your choice green (correct) or red (incorrect) and reveals a teaching explanation with the key answer.
Teaching reference. Numeric thresholds (velocities, indices, biometry, index limits) are representative figures from standard texts and the sources below; they vary with equipment, gestational age, patient factors and local protocol. This sampler is for education and exam practice only. Always follow your department’s protocols and current professional guidance, and use clinical judgement.

Q1PhysicsScanners convert echo return time into depth by assuming one sound speed for all soft tissue. What value is assumed?

Correct: C

Scanners assume an average soft-tissue speed of 1540 m/s when turning echo time into depth. Reference tables give about 330 m/s for air, about 1450 m/s for fat and more than twice the soft-tissue speed for cortical bone. Where the true speed differs from 1540 m/s, echoes are placed at the wrong depth.

Q2PhysicsYou need to scan a deep gallbladder in a patient with a large body habitus, then a superficial thyroid nodule in a slim patient.
Which transducer frequency choice fits both tasks best?

Correct: A

Higher frequencies give finer resolution but are attenuated faster, so they suit shallow targets such as the thyroid. A deep gallbladder in a large patient needs a lower frequency to reach it. Choose the highest frequency that still reaches the depth needed.

Q3DopplerA colour Doppler box over a carotid artery shows a mosaic of colours, and the spectral trace wraps around the baseline.
Which of these adjustments corrects the aliasing?

Correct: D

Aliasing appears when the Doppler shift exceeds the Nyquist limit, half the PRF, so raising the velocity scale corrects it; shifting the baseline also helps. Lowering the scale makes it worse, B-mode gain does not change it, and a higher transmit frequency raises the Doppler shift.

Q4DopplerA renal interlobar artery has a peak systolic velocity (PSV) of 40 cm/s and an end-diastolic velocity (EDV) of 6 cm/s. What is the resistive index?

Correct: B

Resistive index = (PSV − EDV) / PSV = (40 − 6) / 40 = 0.85. The other values come from dividing the wrong pair: 6/40 = 0.15, 40/34 = 1.18 and 40/6 = 6.67. An upper limit of normal of about 0.70 is widely used, so 0.85 is raised.

Q5SafetyOn the scanner display, what do the thermal index (TI) and the mechanical index (MI) indicate, in that order?

Correct: C

TI indicates the potential for thermal effects, a temperature rise in tissue, with soft-tissue, bone and cranial versions. MI indicates the potential for non-thermal effects such as cavitation and is based on peak rarefactional pressure. Keep both as low as reasonably achievable, with short scan times.

Q6ArtifactsA patient with flank pain has an echogenic focus in the kidney with no clear acoustic shadow. Colour Doppler shows a rapidly changing mixture of colours just behind it.
What does this finding represent?

Correct: D

Twinkling is a rapidly alternating colour signal behind a strongly reflective, rough object such as a stone, and it improves ultrasound detection of urinary calculi. Blooming is colour spilling beyond a vessel, reduced by lowering gain, and a mirror artefact duplicates a structure across a strong reflector.

Q7AbdominalA patient presents with right upper quadrant pain.
Which combination of findings most strongly supports acute calculous cholecystitis?

Correct: A

Gallstones combined with a positive sonographic Murphy sign, or with gallbladder wall thickening, strongly predict acute calculous cholecystitis. Wall thickening without stones does not meet that pattern, and a contracted gallbladder after food is expected.

Q8VascularWhat maximum diameter is the conventional threshold for calling an abdominal aorta aneurysmal?

Correct: B

An abdominal aortic aneurysm is defined as an aortic diameter of 3.0 cm or larger. Surgical repair is standard for men with an aneurysm of 5.5 cm or more, and smaller aneurysms are followed with surveillance. Measure with the caliper convention your programme specifies.

Q9Small partsA teenage boy has had sudden, severe pain on one side of the scrotum for three hours.
Which Doppler finding best fits testicular torsion?

Correct: D

Torsion classically shows absent or reduced intratesticular flow compared with the other testis. Partial or intermittent torsion can keep symmetrical or even increased flow, so preserved flow does not exclude it. Hyperaemia of the epididymis or testis points instead to inflammation.

Q10Small partsUnder ACR TI-RADS, which of these thyroid nodule features scores the most points?

Correct: A

In ACR TI-RADS a taller-than-wide shape scores 3 points. Lobulated or irregular margins and peripheral rim calcifications score 2 each, and comet-tail artefacts score 0. Punctate echogenic foci, very hypoechoic nodules and extrathyroidal extension also score 3.

Q11ObstetricHadlock’s estimated fetal weight formulas are built from which inputs?

Correct: C

Hadlock’s formulas estimate fetal weight from head measurements (biparietal diameter, head circumference), abdominal circumference and femur length, the biometry ISUOG lists for estimating weight. Crown–rump length and nuchal translucency are first-trimester dating and screening measures, and fluid and placental measures are not inputs.

Q12ObstetricWhich of these techniques does AIUM recommend for documenting fetal heart rate with a diagnostic scanner?

Correct: B

AIUM’s statement on prudent use in pregnancy recommends an M-mode or B-mode scan with the thermal index kept low, and says spectral Doppler should not document fetal heart rate unless clinically indicated. The WFUMB/ISUOG statement advises against routine pulsed, power or colour Doppler in early pregnancy.

Q13SafetyAn endocavity probe that touches intact mucous membranes is a semicritical device. What is the minimum processing between patients, even when a probe cover was used?

Correct: A

AIUM and ESR guidance require cleaning followed by high-level disinfection for endocavity probes, with a cover for every examination. Covers can perforate or leak, so using one does not lower that requirement. Low-level disinfection is enough for probes used on intact skin; for needle procedures guidelines differ (see the ultrasound safety page).

Q14VascularUnder the 2003 Society of Radiologists in Ultrasound consensus criteria, which internal carotid peak systolic velocity indicates stenosis of 70% or more, short of near-occlusion?

Correct: D

The SRU consensus grades 70% or greater stenosis, short of near-occlusion, by an ICA peak systolic velocity above 230 cm/s, supported by an end-diastolic velocity above 100 cm/s and an ICA/CCA ratio above 4. A PSV above 125 cm/s with plaque indicates at least 50%.

PRO

The full ultrasound question bank is coming with Pro

You have completed the free 14-question sampler. The full bank will cover the ARDMS exam content and the topics of ASAR- and CASE-accredited courses, with detailed explanations, image-based stems and progress tracking.

  • Topic sets: physics & instrumentation (SPI), abdomen, OB/GYN, vascular (RVT), echocardiography, small parts, MSK and point-of-care
  • Fully worked explanations with source citations and “why the distractors are wrong”
  • Timed mock exams, weak-topic analytics and spaced-repetition review
  • Image-based questions: recognise artifacts, measure biometry, grade stenosis

What Pro will include →

Everything on this page is free today.

Sources

22 sources listed

  1. Grant EG, Benson CB, Moneta GL, et al. Carotid artery stenosis: gray-scale and Doppler US diagnosis — Society of Radiologists in Ultrasound consensus. Radiology 2003;229:340–346. rsna.org
  2. Intersocietal Accreditation Commission. Updated recommendations for carotid stenosis interpretation criteria (2023). intersocietal.org
  3. US Preventive Services Task Force. Screening for abdominal aortic aneurysm: recommendation statement (2019). uspreventiveservicestaskforce.org
  4. Tessler FN, Middleton WD, Grant EG, et al. ACR Thyroid Imaging, Reporting and Data System (TI-RADS): white paper of the ACR TI-RADS Committee. J Am Coll Radiol 2017;14:587–595. jacr.org
  5. Hadlock FP, Harrist RB, Sharman RS, et al. Estimation of fetal weight with the use of head, body, and femur measurements. Am J Obstet Gynecol 1985;151:333–337.
  6. American Institute of Ultrasound in Medicine. Prudent use and safety of diagnostic ultrasound in pregnancy. AIUM official statement, approved 19 May 2020. aium.org
  7. British Medical Ultrasound Society (BMUS). Guidelines for the safe use of diagnostic ultrasound equipment (TI/MI, exposure). bmus.org
  8. Westerway SC, Basseal JM, Abramowicz J, et al.; WFUMB Safety Committee. Recommendations for the cleaning of endocavity ultrasound transducers between patients. Ultrasound Med Biol 2024;50(6):775–778. doi:10.1016/j.ultrasmedbio.2024.02.011
  9. CDC. Disinfection and sterilization: Spaulding classification of medical devices. cdc.gov
  10. Salomon LJ, Alfirevic Z, Da Silva Costa F, et al. ISUOG Practice Guidelines: ultrasound assessment of fetal biometry and growth. Ultrasound Obstet Gynecol 2019;53(6):715–723. doi:10.1002/uog.20272
  11. WFUMB/ISUOG. WFUMB/ISUOG statement on the safe use of Doppler ultrasound during 11–14 week scans (or earlier in pregnancy). Ultrasound Med Biol 2013;39(3):373. doi:10.1016/j.ultrasmedbio.2012.11.025
  12. Nyhsen CM, Humphreys H, Koerner RJ, et al. Infection prevention and control in ultrasound: best practice recommendations from the European Society of Radiology Ultrasound Working Group. Insights Imaging 2017;8(6):523–535. doi:10.1007/s13244-017-0580-3
  13. Bhatt S, Dogra VS. Role of US in testicular and scrotal trauma. RadioGraphics 2008;28:1617–1629.
  14. Ralls PW, Colletti PM, Lapin SA, et al. Real-time sonography in suspected acute cholecystitis: prospective evaluation of primary and secondary signs. Radiology 1985;155:767–771.
  15. Poggi C, Palavecino M. Ultrasound principles and instrumentation. Surg Open Sci 2024;18:123–128. doi:10.1016/j.sopen.2024.02.005
  16. Moyano DB, Paraiso DA, González-Lezcano RA. Possible effects on health of ultrasound exposure, risk factors in the work environment and occupational safety review. Healthcare (Basel) 2022;10(3):423. doi:10.3390/healthcare10030423
  17. Feldman MK, Katyal S, Blackwood MS. US artifacts. RadioGraphics 2009;29(4):1179–1189. doi:10.1148/rg.294085199
  18. Terslev L, Diamantopoulos AP, Døhn UM, et al. Settings and artefacts relevant for Doppler ultrasound in large vessel vasculitis. Arthritis Res Ther 2017;19(1):167. doi:10.1186/s13075-017-1374-1
  19. Darabont R, Mihalcea D, Vinereanu D. Current insights into the significance of the renal resistive index in kidney and cardiovascular disease. Diagnostics (Basel) 2023;13(10):1687. doi:10.3390/diagnostics13101687
  20. Kamaya A, Tuthill T, Rubin JM. Twinkling artifact on color Doppler sonography: dependence on machine parameters and underlying cause. AJR Am J Roentgenol 2003;180(1):215–222. doi:10.2214/ajr.180.1.1800215
  21. Nabheerong P, Kengkla K, Saokaew S, et al. Diagnostic accuracy of Doppler twinkling artifact for identifying urolithiasis: a systematic review and meta-analysis. J Ultrasound 2023;26(2):321–331. doi:10.1007/s40477-022-00759-z
  22. Bandarkar AN, Blask AR. Testicular torsion with preserved flow: key sonographic features and value-added approach to diagnosis. Pediatr Radiol 2018;48(5):735–744. doi:10.1007/s00247-018-4093-0

Educational use only. Verify all velocity thresholds, biometric formulae, index limits and disinfection standards against current guidelines and your local protocols before clinical application.

More in Question banks and mocks

Next in Question banks and mocks: Ultrasound credentials by country

Educational reference for imaging professionals. It does not replace local policy, manufacturer labelling or clinical judgement.